GDBT-8610P Su'esu'ega Fa'aletonu o Maa
GDBT-8610P Battery Tester e faʻaaogaina lautele i vaega nei:
● Telecom: Ofisa Tutotonu, nofoaga autu o faʻamaumauga ma Nofoaga Mamao
●Power Utility: Switchgear, Power Station and Power Plant
●Fa'alapotopotoga Tau Tupe: Nofoaga Autu o Fa'amaumauga Autasi
●Petrochemical: Fa'agasologa Pulea faiga
●Fa'asao i fafo
●Malo: Fa'alotoifale ma fa'aitulagi
●Lafoga ma Tupe Maua Nofoaga Autu
●Saogalemu ile Atunuu, Aoga, Vaegaau ma le Neivi
●Fa'asaienisi a le Ea, Fuimu ma Leoleo
● Falema'i UPS faiga
●Taavale eletise
●SLA maa gaosia
●Wide suʻega suʻega: 5 ~ 6000Ah, fetaui mo sela tasi o 1.2V, 2V, 6V ma 12V
●Masini atamai ma feavea'i u'u lima, gaoa ma faigofie ona alu
●Fulu felanulanua'i pa'i ma faagaioiga filifiliga o le piano
●I le taimi lava e tasi su'esu'e mo voltage, tete'e ma le gafatia fuafuaina o ma'a
●Faʻatatau i luga ole laiga, leai se manaʻoga e aveese le maa ma le manoa mai lona faiga mo suʻega, saogalemu ma faigofie
● Fa'ata'ita'iga vave mo maa ma manoa i sekone fa'atasi ai ma fa'ata'ita'iga fa'amaumauga fa'aola
● Malosi faʻalavelave faʻalavelave i le maualuga o le taimi nei ma le faʻatinoina ma le saʻo
●Su'ega taimi maualalo ifo than10 Hz, lelei aloese mai faalavelave mai capacitive tetee o maa lava ia
●Tu'usa'o le ta'avale USB mo le fa'afouina o polokalama ma fa'aliliuina fa'amaumauga i le PC mo le su'esu'eina atili
●Mamana PC pulega polokalama, faigofie mo le teuina o faamatalaga ma le auiliiliga
●Manatua tele mo le suʻeina o faʻamaumauga o faʻamaumauga e sili atu i le 3000 sela
●Buzzer Alarm Function and over voltage protection, saogalemu e fa'aoga
●Auto-calibration galuega aʻo leʻi faʻataʻitaʻiina, faʻaleleia le saʻo o le suʻega
● Toe su'esu'e ma taui galuega: so'o se fa'agaioiga fa'aletonu po'o le le faia e mafai ona toe su'esu'e ile kiliki tasi
●Fa'amatalaga fa'asino i totonu o manatuaga mo le fa'atusatusaga o lau su'ega, ma o lo'o avanoa fa'atatau mo oe lava fa'asino
Tete'e laina | 0.00mΩ ~ 100mΩ | Voltaisi laina | 0.000V ~16V* |
Min i'uga ole su'ega-voltage -tetee
| 1mv 0-999μΩ: 1μΩ 1-9mΩ: 10μΩ(0.01mΩ) 10-99mΩ: 100 μΩ(0.1mΩ) | Su'ega sa'o -voltage -tetee
| ±0.2%rdg ±6dgt 0μΩ-250μΩ: 8%±6DGT 250μΩ-500μΩ: 3%±6DGT 500μΩ-100mΩ: 1%±6DGT |
Paoa sapalai | 7.2V 2400mAhLi-ion maa | Taimi faigaluega | E sili atu i le 5 itula pe a uma ona totogi atoa |
Fuaina o fa'amaumauga manatua | 3000 sela | Siosiomaga o galuega | 0 ℃ i le 40 ℃90% RH |
fa'aaliga LCD | 320*240 pika TFT mata pa'i | Fua(iunite autu) | L210*W110*H60 mm |
mamafa mama(fa'aiga) | 2 kilokalama | Com uafu | Mini USB |