GDYT-350kVA/70kV PD free Resonant Test System e aofia ai le PD free fesuia'i fa'avevesi mana sapalai, pusa fua HV, transformer excitation, transformer vavae ese, reactor Resonant, ma capacitive voltage divider.

 

 

 

 

 


Fa'amatalaga Oloa

Faailoga o oloa

GDYT-350kVA/70kV PD free Resonant Test System e aofia ai le PD free fesuia'i fa'avevesi mana sapalai, pusa fua HV, transformer excitation, transformer vavae ese, reactor Resonant, ma capacitive voltage divider.
O lenei faiga su'ega e leai se fa'afitauli o le tele o le taimi amata.O le fa'aaogaina o le la'ititi la'ititi o le mana e mafai ona fa'amae'a ai se su'ega e tutusa ma le 30 i le 60 taimi o le fa'aogaina o le eletise, lea e matua fa'aitiitia ai le fa'afitauli o le le lava o le malosi ole su'ega eletise.

Vaega

Saogalemu ma faatuatuaina.E i ai le tele o galuega tauave, e aofia ai le lafoaia ma le malepelepe puipuiga, ova-voltage ma le ova o le taimi nei le faatulagaga o le puipuiga, le malosi o le suega mai le puipuiga, leai se puipuiga, puipuiga o le vevela ma isi. Pe a tupu so o se puipuiga, o le a vave motusia le faiga ma le malosiaga, ia mautinoa le saogalemu o tagata faʻatautaia, faiga faʻataʻitaʻiga ma mea faʻataʻitaʻi.
Fa'atino faigofie ma faigofie uaea.
320 * 240 LCD faʻaaliga, faʻaalia le voluma faʻaalia, gaioiga o loʻo i ai nei, taimi, vevela o le siosiomaga, faʻasologa o galu, aso, taimi ma isi.
Otometi su'esu'e resonant frequency, fa'atulagaina otometi taimi.
Su'ega voltage ma le taimi e mafai ona seti.
Ole fua ole fa'asesega ole galu o le HV e maualalo ifo ile 1%, e leai se mea e fa'aleagaina ile mea fa'ata'ita'i.
Fa'aoga totonu po'o fafo.Faatasi ai ma matau, talafeagai mo le sisiina i luga o le nofoaga.

Tulaga Fa'aoga Lautele

Maualuluga: ≤ 3000m.
Siosiomaga vevela: -10 ℃ i le 40 ℃.
Teuga vevela: -20 ℃ i le 50 ℃
Malosi o le la: 0.1W/cm2 (savili savili 0.5m/s)
Max.Eseesega o le vevela i aso uma: 25℃.
Fa'aaogaina i le leai o se pefu conductive, leai se afi ma leai se pa, corrosive nofoaga saoloto.
Fa'aoga i fafo po'o totonu.Teuga i totonu.
E tatau ona maua le fa'amaufa'ailoga fa'alagolago ile eleele, fa'asao ole eleele <0.5Ω
Ole fa'apipi'i fa'alili ole reactor e le tatau ona sili atu ile 5°.