Meafaigaluega Su'u Suauu

  • GDFJ-VI Transformer Dissolved Gas Analyzer

    GDFJ-VI Transformer Dissolved Gas Analyzer

    GDFJ-VI Transformer Dissolved Gas Analyzer ose chromatograph kasa feavea'i talafeagai mo su'esu'ega vave i luga ole laiga.E tu'ufa'atasia le su'esu'eina o le chromatographic, au'ili'ili ma su'esu'ega i le tasi, fa'apea fo'i ma le micro detector, tama'i gas puna ma fausia-i totonu o le komepiuta mata pa'i.

  • GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator)

    GDW-102 Su'u Su'u Su'ega Su'ega (Coulometric Karl Fischer Titrator)

    Coulometric Karl Fischer tekinolosi ua faʻaaogaina e fuaina saʻo le susū o le fua faʻataʻitaʻiga o loʻo aofia ai le tekonolosi mo le saʻo ma le taugofie o le suʻega tau. O le Faʻataʻitaʻiga GDW-102 fuaina saʻo susū i luga o vai, malosi ma kesi faʻataʻitaʻiga e tusa ai ma tekinolosi.

  • GDOH-II insulating Oil Gas Content Tester

    GDOH-II insulating Suau'u Kasa mea su'ega

    GDOH-II Insulating Oil Gas Content Tester ose tupulaga fou su'ega fa'aaogaina fa'aulufale mai maualuga le sa'o sa'o ma le tekonolosi fa'afouga fou.O lo'o fa'avae i luga ole DL423-91 fa'atauga eletise ma tulaga fa'atatau a le atunu'u.

  • GDW-106 Oil Dew Point Tester User’s Guide

    GDW-106 Su'u Su'u Dew Point Su'e Taiala

    O le vaitaimi o le warranty mo lenei fa'asologa o le TASI le tausaga mai le aso na lafo ai, fa'amolemole fa'afeso'ota'i lau pili po'o lau pepa fa'amomoli e iloa ai aso fa'amaonia talafeagai.E fa'amaonia e le kamupani HVHIPOT le fa'atau muamua o lenei oloa o le a leai ni fa'aletonu i meafaitino ma galuega i lalo ole fa'aoga masani.

  • GDSZ-402 Automatic Acid Value Tester

    GDSZ-402 Otometi Su'e Tau Su'ega Su'ega

    Automatic Acid Value Tester ua mamanuina mo le suʻeina o le aoga o le suauʻu suauʻu, suauʻu turbine ma le suauʻu faʻafefe afi ma isi mea. PC pulea lelei e mafai ona faʻaleleia le lelei o le galuega ma faʻaitiitia ai le afaina i solvents organic ma vailaʻau i le tino o le tagata.

  • GDZL-50L Oil Filtration Machine

    GDZL-50L Su'u Suauu Filtration Machine

    O le masini GDZL-50L e mafai ona faʻaleleia lelei le susu, kesi ma mea le mama i totonu o le suauʻu faʻafefe, faʻaleleia le malosi o le suauʻu ma le lelei o le suauʻu, ia mautinoa le saogalemu o le faʻaogaina o meafaigaluega eletise.

  • GDBS-305  Automatic Flash Point Closed Cup Tester

    GDBS-305 Su'e Ipu Tapuni Ipu Fa'ailoga Fa'ata

    GDBS-305 otometi tapuni ipu moli mata'itusi o le masini su'ega ipu tapuni mata moli mo oloa suauu.E faʻaogaina le mamanu faʻatulagaina lea e mafai e se tasi talimalo ona pulea le tele o ogaumu suʻega, e faʻataʻitaʻi ai faʻataʻitaʻiga eseese i le taimi e tasi pe vavae ese.

  • GDKS-205  Automatic Flash Point Open Cup Tester

    GDKS-205 Su'e Ipu Tatala Su'ega Ipu Mata'i'i

    GDKS-205 otometi tatala ipu moli mata'itusi o le masini su'ega ipu malamalama mata'itusi mo oloa suauu.E faʻaogaina le mamanu faʻatulagaina lea e mafai e se tasi talimalo ona pulea le tele o ogaumu suʻega, e faʻataʻitaʻi ai faʻataʻitaʻiga eseese i le taimi e tasi pe vavae ese.

  • GDCP-510 Oil Freezing Point Tester

    GDCP-510 Su'u Su'u Fa'a'aisa Point Su'e

    GDCP-510 Low Temperature Colzing Point Tester e ogatasi ma le GB/T 510 “Determination of Solidification Point for Petroleum Products” ma le GB/T 3535 “Petroleum Products–Determination of Pour Point.

  • GDND-800 Freezing Point Tester

    GDND-800 Su'ega Fa'a'aisa

    Suau'u suau'u suau'u su'esu'e fa'a'aisa e iai uiga o le fa'atulagaina matagofie ma le fa'agasologa o gaosiga tulaga ese.E ogatasi ma GB / T 3535 ma GB / T510 tulaga ma faʻaaogaina e fuafua ai le sasaa o mea tau suauu.

  • GDYN-901 Kinematic viscosity tester

    GDYN-901 Kinematic viscosity su'ega

    GDYN901 e fetaui lelei e fuafua ai le viscosity kinematic o oloa suauʻu suavai.O lenei meafaigaluega o loʻo i ai le aoga o le taimi o le faʻataʻitaʻiga faʻataʻitaʻiga faʻataʻitaʻiga ma e mafai ona faʻatusatusa le iʻuga mulimuli o le kinematic viscosity.

  • GDC-9560B Power System Insulation Oil Gas Chromatograph Analyzer

    GDC-9560B Power System Insulation Suau'u Gas Chromatograph Analyzer

    GDC-9560B Gas Chromatograph Analyzer o le suʻeina lea o le kesi o loʻo i totonu o le suauʻu faʻapipiʻi e ala ile kesi chromatographic metotia.E aoga tele le fa'amasinoina pe iai ni fa'aletonu e pei o le vevela tele, fa'amalo pe leai, ina ia mautinoa le saogalemu o le eletise.

12Sosoo ai >>> Itulau 1 / 2