Su'ega Su'ega Voltage Maualuga AC mo GIS
●Transformer
●GIS faiga
●SF6 switchge
●Uaea
●Fa'asalaina
●Insulator
●CT/PT
●Isi masini capacitive
●Laititi le vevela e si'itia ile uta fa'atatau.Fa'amamago po'o Suau'u ituaiga reactors, malosi fa'ainisinia maualuga, fa'amama lelei, manaia ma fa'atuatuaina.
●E mafai ona fetu'una'i le malosi ole puna fa'atonutonu ole alaleo.Malosi puipuiga, mautu lelei.Faatasi ai ma le tele o faiga galue, faigofie ona faagaoioia.
●Fa'atasi ai ma le 220V po'o le 380V tasi vaega malosi, faigofie mo sourcing malosiaga i luga o le nofoaga.
●fetuutuunai fetuutuunai.Reactors ituaiga eseese mo le filifiliga, faʻafetaui manaoga mea faitino suʻega eseese.Multifunctional, taugofie.
●Fuafuaina le voluma: fa'avae i luga ole su'ega mea eseese.
●Fa'aoso fa'alava: 20- 300Hz.
●Galu: galu sine mama, THD <1.0%.
●Max.malosi: 1000kVA ma lalo.
●Ta'amilosaga Tiute: Taimi galue faifaipea 15mins tasi le taimi ile malosi atoatoa.(poʻo manaʻoga o tagata faʻatau.)
●Fetuuna'iga fetuutuuna'i taimi: 0.1Hz, le mautu <0.05%.
●Malosiaga Tuuina atu: 380 / 220V ± 15% / 50Hz ± 5%.
GDTF-108/108 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-108 |
Malosiaga (kVA) | 108 |
Fa'aoga lautele | 31500kVA poʻo lalo ifo |
35kV eletise eletise | |
35kV va'a ta'avale ma pa pasi, insulators | |
10kV (300 mm²) uaea 2000m | |
35k V (300 mm²) uaea 500m | |
Fa'atonuga autu | 5kW Fa'afeso'ota'i alavai puna 1 seti |
5kVA Transformer fiafia 1 seti | |
Reactors 27kV/1A 4sets | |
Vaevae malosi 100kV | |
GDTF-216/216 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-216 |
Malosiaga (kVA) | 216 |
Fa'aoga lautele | 110kV Va'a ta'avale ma pa pasi |
110kV GIS | |
35kV(300 mm²) uaea 1500m | |
10kV(300 mm²) uaea 3km | |
110kV Insulation atoa Transformer | |
Fa'atonuga autu | 10kW Fa'afeso'ota'i alavai puna 1 seti |
10kVA Transformer fiafia 1 seti | |
Reactors 54kV/1A 4sets | |
Vaevae malosi 200kV | |
GDTF-270/270 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-270 |
Malosiaga (kVA) | 270 |
Fa'aoga lautele | 110kV GIS ma transformer |
110kV GIS ma transformer | |
35kV (300 mm²) uaea 2km | |
Fa'atonuga autu | 15kW Fa'afeso'ota'i alavai puna 1 seti |
15kVA Transformer fiafia 1 seti | |
Reactors 54kV/1A 5sets | |
Vaevae malosi 300kV | |
GDTF-400/400 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-400 |
Malosiaga (kVA) | 400 |
Fa'aoga lautele | 220kV GIS ma transformer |
10kV (300 mm²) uaea 4km | |
35kV (300 mm²) uaea 1km | |
Fa'atonuga autu | 20kW Fa'afeso'ota'i alavai puna 1 seti |
20kVA Transformer fiafia 1 seti | |
Reactor | |
Vaevae malosi 400kV | |
GDTF-520/260 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-260 |
Malosiaga (kVA) | 520 |
Fa'aoga lautele | 110KV Va'a ta'avale ma pa pasi |
110kV GIS | |
110kV (300 mm²) uaea 800m | |
35kv (300 mm²) uaea 3km | |
10kV (300 mm²) uaea 6km | |
110kv Insulation atoa Transformer | |
Fa'atonuga autu | 25kW Fa'afeso'ota'i alavai puna 1 seti |
25kVA Transformer fiafia 1 seti | |
Reactor 65kV/2A 4sets | |
Vaevae malosi 300kV | |
GDTF-500/500 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-500 |
Malosiaga (kVA) | 500 |
Fa'aoga lautele | 220kV po'o lalo CT/PT |
220kV po'o lalo ifo o fa'atosina | |
220kV pe i lalo Insulators, motumotu | |
220kV po'o lalo ole va'a va'aia | |
220kV po'o lalo ifo Meafaigaluega Insulation | |
Fa'atonuga autu | 20kW Fa'afeso'ota'i alavai puna 1 seti |
20kVA Transformer fiafia 1 seti | |
Reactor 125kV/1A 4sets | |
Vaevae malosi 500kV | |
GDTF-600/600 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-600 |
Malosiaga (kVA) | 600 |
Fa'aoga lautele | 110kV (300 mm²) uaea 800m |
35kv (300 mm²) uaea 110m | |
35-220kV GIS, transformers, insulators | |
Fa'atonuga autu | 30kW Fesuia'i alavai puna 1 seti |
30kVA Transformer fiafia 1 seti | |
Reactor 120kV/1A 5sets | |
Vaevae malosi 600kV | |
GDTF-800/800 | |
Malosi'i totonu (V) | 380 |
Volosa (kV) | 0-800 |
Malosiaga (kVA) | 800 |
Fa'aoga lautele | 110kV (300 mm²) uaea 800m |
220kv (300 mm²) uaea 500m | |
35-500kV GIS, transformers, insulators | |
Fa'atonuga autu | 40kW Fa'afeso'ota'i alavai puna 1 seti |
40kVA Transformer fiafia 1 seti | |
Reactor 200kV/1A 4sets | |
Vaevae malosi 800kV |