GD6900 Capacitance ma Dissipation Factor Tester
GD6900 fuaina le capacitance ma le dielectric mea leiloa (tgδ) o eletise eletise eletise maualuga.O loʻo tuʻufaʻatasia le fausaga, fausia-i le alalaupapa suʻega dielectric gau, fesuiaʻi taimi fetuutuunai sapalai mana, faʻaleleia transformer ma SF6 capacitor tulaga.
Ole puna eletise maualuga e maua mai i totonu ole inverter ole meafaigaluega, lea e faʻaaogaina mo le suʻeina o mea faʻataʻitaʻi pe a uma le suiga o le transformer.Afai e fa'aopoopoina se ipu fa'a'ese'ese ma masini e pulea le vevela, e mafai ona fa'ata'ita'i le leiloa o le suau'u fa'amama.
●Pa'i fa'aali mata LCD.
●Fuafuaga fa'agata fa'amama: Fa'atupu-i totonu o le fa'a'ese'esega fa'ata'ita'iga su'ega, e mafai ona fa'atino le fa'aogaina o le Insulation resistance (IR), absorption ratio (DAR), polarization index (PI) su'ega.
●Kalena pulou ma le tele e teu ai totonu.Fa'asao fa'ai'uga o su'ega e tusa ai ma fa'atonuga taimi, siaki tala fa'asolopito ma lolomi le taunu'uga.
●E mafai ona auina atu fa'amatalaga meafaigaluega e ala ile U disk.
●Faiga faʻataʻitaʻiga tele, faʻatasi ai ma faʻataʻitaʻiga o totonu maualuga voltage, fafo maualuga voltage, tulaga i totonu, tulaga i fafo, GST / UST, faʻafiafiaga a le tagata lava ia.Volosa maualuga (sili atu nai lo le 10kV) su'ega gau dielectric e mafai ona faia i le tulaga o tulaga i fafo i fafo atu o voltage maualuga.
●Su'ega atoa fa'amaufa'ailoga CVT (Capacitive Voltage Transformer) C1 ma C2 dielectric gau ma capacitance i le taimi e tasi.Fa'ata'ita'i fo'i le fua faatatau o suiga o le CVT ma le eseesega o le maualuga o le voltage.
●O le gau o le dielectric ma le tau gafatia o C0 i le pito i luga o le CVT e mafai ona fuaina e ala i le faʻaaogaina o le auala e puipuia ai.
●Faʻailoga faʻataʻitaʻiga maualuga maualuga.O le Inverter ma le sampling circuit i totonu o lo'o fa'atonutonuina numera.E fetuutuuna'i pea le voluma o fafo.
●LCR fua otometi.Inductance, capacitance, tetee, maualuga e mafai ona fuaina ma faʻaalia.
●Le tele o puipuiga o le fesuiaiga o le eletise, gaioiga puʻupuʻu puʻupuʻu, ova-voltage, sili atu i le taimi nei, vevela, saogalemu ma faʻatuatuaina.I le taimi nei, o loʻo i ai le galuega o suʻega faʻavae, e le faʻatagaina le faʻamalosia o le voltage mo mea e le faʻavaeina.
●Leai se mana'oga e fa'ate'aina le HV ta'ita'i e fua ai le gau ma le malosi o le CVT.
●E mafai ona suia le taimi i le 50Hz, 47.5Hz/52.5Hz, 45Hz/55Hz, 60Hz, 57.5Hz/62.5Hz, 55Hz/65Hz.
Tulaga galue | -15℃~40℃ | RH<80% | ||||||
Fa'atonuga fa'alavelave | Fa'aliliuga faifaipea | |||||||
Paoa sapalai | AC 220V±10%, 50/60Hz | E mafai ona fa'aogaina le afi. | ||||||
Tuuina atu eletise maualuga | AC 0.5KV~10KV (12kV faitalia) | 0.1kV uma | ||||||
Sa'o | 2% | |||||||
Max.taimi nei | 200mA | |||||||
Malosiaga | 2000VA | |||||||
Mana fa'afiafiaina o ia lava | AC 0V~50V/15A | 50Hz, 60Hz tasi taimi 45HZ/55HZ 47.5HZ/52.5HZ 55HZ/65HZ 57.5HZ/62.5HZ Otometi fa'alua taimi | ||||||
I'ugafono | tg: 0.001% | Cx: 0.001pF | ||||||
Sa'o | ∆tgδ: ±(faitau*1.0%+0.040%) | |||||||
∆C x: ±(faitau*1.0%+1.00PF) | ||||||||
Va'aiga fua | tgδ | E aunoa ma se tapulaa | ||||||
C x | 15pF <Cx <300nF | |||||||
10KV | Cx <60 nF | |||||||
5KV | Cx <150 nF | |||||||
1KV | Cx <300 nF | |||||||
Su'ega CVT | Cx <300 nF | |||||||
LCR fua fa'atatau | L>20H(2kV) | R>10KΩ(2kV) | ||||||
Sa'o le fua ole LCR | 0.1% | I'ugafono | 0.01 | |||||
CVT fua fa'atatau | 10~10000 | |||||||
CVT fua sa'o sa'o | 0.1% | |||||||
CVT fua faatatau iugafono | 0.01 | |||||||
Tete'e puipui | DC maualuga voltage | 5~10kV | Sa'o | ±(2%* Faitau +10V) | ||||
IR sa'o | 100kΩ-1000GΩ: <5% (su'ega voltage e le itiiti ifo i le 250V) 100GΩ-1000GΩ: 10% (su'ega voltage e le itiiti ifo i le 10000V) | |||||||
Fua | Vaega autu: 350(L)×270(W)×270(H) | |||||||
Pusa fa'aopoopo: 350(L)×270(W)×160(H) | ||||||||
Malosiaga mafaufau | 200 vaega, USB flash disk teuina e lagolagoina. | |||||||
mamafa | Vaega autu: 22.75Kg | |||||||
Pusa fesoasoani: 5.25Kg |
Tagata su'e | 1 seti |
Pusa fa'aoga | 1 fasi |
HV mumu mumu ta'ita'i 8m | 1 fasi |
LV lanu uliuli ta'ita'i 8m | 1 fasi |
Uaea eletise 1.8m | 1 fasi |
CVT Feso'ota'i ta'ita'i 5m | 1 fasi |
Ta'a eleele 2m | 1 fasi |
Lomi pepa | 2 taaiga |
10A fusu | 3 fasi |
Taiala a Tagata Fa'aoga | 1 kopi |
Lipoti o Su'ega Falegaosimea | 1 kopi |
Mea fa'aoga e filifili ai | |
Suauu Su'e Su'e sela | 1 pc |
Pule fa'avevela | 1 pc |
Fa'atasi ai ma le suau'u su'ega suau'u ma fa'avevela fa'atonu, e mafai e le tagata fa'aoga ona su'e tan delta o vai dielectric e pei o le suau'u transformer.
Pule fa'avevela
Vaa suauu