E fa'afefea le fua ole Su'ega Fa'aauau ole Lalolagi Fa'afuainumera Grounding Down Lead?

E fa'afefea le fua ole Su'ega Fa'aauau ole Lalolagi Fa'afuainumera Grounding Down Lead?

GDDT-10U gDigital Grounding Down Lead Earth Continuity Tester o se su'ega feavea'i fa'aautomatika na fausia e la matou kamupani.E fa'aaogaina e fua ai le fa'aauauina o le tete'e tau i le va o ta'avale fa'alalo i lalo o masini eletise eseese i totonu o le substation.O le meafaigaluega o loʻo faʻatonutonuina e se microcomputer tasi-chip maualuga, lea e mafai ona iloa ai le suʻega atamai.E laʻititi i le lapopoa, faigofie ona feaveaʻi, faigofie i le faʻaogaina, maualuga i le saʻo, vave i le saoasaoa o le suʻega, lelei i le toe faʻaaogaina ma le malamalama i le faitau.O se meafaigaluega faʻapitoa faʻapitoa e fetaui ma manaʻoga o tulafono faatonutonu.

                                                           接地引下线导通测试仪

                                                                                 HV HIPOT GDDT-10U Fa'afuainumera Fa'alalolalo Ta'ita'i Fa'aauau le Su'ega Fa'aauau

E fa metotia su'esu'e mo le su'ega fa'aauau pea o le ta'avale fa'avae:

Muamua: ole fua ole multimeter.Fa'aaoga se multimeter e fua ai pe o iai se tau fa'afeagai i le va o le ta'ita'i fa'avae ma le laina fa'alalo po'o le va o mea faigaluega lata ane.Afai ei ai se tau tetee, e tatau ona e toesea le taʻitaʻi tetee, ma o le fua fua e maua pe a uma ona toesea.O lenei metotia e sili atu ona faigofie ma faigofie ona fuaina, ae o faʻamaumauga e itiiti ifo le saʻo.

Ole auala lona lua: ole fua ole laulau lulu eleele.O lenei metotia e tutusa ma le multimeter metotia fua, ae sili atu le aoga.

O le ituaiga lona tolu: fuaina le faʻaogaina o le faʻaogaina o le faʻaogaina o le faʻavae.E manaʻomia e tagata uma ona faʻafesoʻotaʻi le laina pito i lalo mai masini eletise uma.A mae'a le feso'ota'iga, e fa'ata'ita'i ma fa'atusatusa le tau fa'atatau o le impedance o le eleele.Ole tau ole impedance tele ole feso'ota'iga leaga.E masani ona tatou le filifili e faʻaoga lenei metotia fua, aua o lenei metotia e masani lava ona galue malosi ma faʻaalu taimi, o le saʻo o faʻamaumauga fuafuaina e le maualuga, ma e le faigofie le iloagofie, o lea e seasea fuaina i lenei metotia. .

Le ituaiga lona fa: metotia fa'apitoa e fua ai meafaigaluega.O le faʻaauau fuaina meafaigaluega e faʻapitoa ona faia e ala i le faʻaaogaina o le mataupu faavae o le alalaupapa lua.Faatasi ai ma lenei meafaigaluega, o le aafiaga o uaea taʻitaʻia ma le faʻafesoʻotaʻi tetee e mafai ona matua faʻaumatia.O faʻamaumauga fua e saʻo ma aoga foi, ma ona o le auala e faigofie, o le leiloa o le tagata faigaluega e laʻititi lava.Ose metotia fua fa'aaoga lautele i le taimi nei.Ole su'ega fa'aauau ole fa'avae ma lalo ole fa'aogaina o lo'o fa'aogaina nei e maualuga le sa'o ma le fa'ai'uga, ma e lelei fo'i le lelei ole su'esu'eina.