GDPD-414 Su'esu'e Fa'asa'o Fa'atasi

GDPD-414 Su'esu'e Fa'asa'o Fa'atasi

Fa'amatalaga Puupuu:

O le GDPD-414 Portable Partial Discharge Detector e faʻaaogaina le Smart Quick intelligent power test system, ma o se mea faigaluega faʻapipiʻi faʻalotoifale feaveaʻi mo mea faigaluega faʻapipiʻi eletise maualuga.

 

 

 


Fa'amatalaga Oloa

Faailoga o oloa

GDPD-414 Portable Partial Discharge Detector01
GDPD-414 Portable Partial Discharge Detector02
GDPD-414 Portable Partial Discharge Detector03

Autu
iunite

UHF sensor,
ituaiga lapotopoto,talafeagai mo GIS

UHF sensor, rectangle type, talafeagai mo le eletise eletise, transformer, switchgear

GDPD-414 Portable Partial Discharge Detector04
GDPD-414 Portable Partial Discharge Detector05
GDPD-414 Portable Partial Discharge Detector06

HFCT, talafeagai mo le eletise eletise, transformer

TEV sensor,
talafeagai mo switchgear

Ultrasonic sensor, talafeagai mo transformers, switchgear

GDPD-414

O ata o loʻo i luga e naʻo le faʻamatalaga muamua.

O le GDPD-414 Portable (GDPD-414H handheld) Partal Discharge Detector e faʻaaogaina le faiga faʻataʻitaʻiga faʻataʻitaʻi faʻapitoa (Soft Nu. 1010215, numera resitalaina 14684781 (14684481)).E mafai ona fetuutuunai configure sensors eseese e tusa ai ma oloa eseese e tofotofoina.TEV, ultrasonic ma HFCT e talafeagai mo le suʻeina o vaega faʻasalalau o le maualuga-voltage switchgear ma le kapoti fesoʻotaʻiga mama;Ultrasonic ma UHF e talafeagai mo le suʻeina o le GIS;Ultrasonic ma HFCT e talafeagai mo le suʻeina o le eletise eletise.E mafai ona fa'avasegaina fa'amaumauga o su'ega ma fa'amasinoina le malosi o le fa'amalo ma vaega e mafai.E fa'aaogaina lautele i le eletise ma le nofoaafi.

GDPD-414 Portable Partial Discharge Detector07

Ultrasonic ma le TEV sensor (2-in-1)

Vaega

Fa'aaoga laupapa fa'ata'ita'iga DSP/FPGA maualuga, 4-auala fa'atasi fa'amaumauga maua.
Polokalama polokalame: su'esu'ega polokalama fa'avae i luga o le ARM fa'apipi'i faiga
6/8/16 auala e mafai ona configured
8.1 inisi papalama po'o le api Thinkpad pe a filifili
6/8/16 auala e mafai ona configured e tusa ai ma manaoga eseese o tagata faatau.
E mafai ona fa'aali fa'afanua PRPS ma PRPD, fa'afanua ellipse, fa'afanua fua faatatau, fa'afanua QT, fa'afanua NT, fa'afanua fa'aopoopo PRPD, fa'afanua fai-QN o alavai ta'itasi.
 E tolu-lanu faʻailoga faʻailoga o le mumu, samasama ma le lanumoana e faʻaalia ai le ogaoga o le tuʻuina atu o vaega.

 

E mafai e le tagata fa'atau ona filifili masini e tusa ai ma mea fa'ata'ita'i eseese:

Sensors

TEV/AE/HFCT

AE/UHF

AE/HFCT

 

Mea Tofotofoina

HV Swichgear ma Ring network cabinet

 

GIS

 

Uaea

 

 

GDPD-414 / GDPD-414H Fa'amatalaga
PD faʻailoga mauaina faʻailoga
PPU Galulue fa'atele 1.2GHz / 800MHz
Faiga fa'agaioiga Linx fa'aogaina faiga fa'aoga
Tau feso'ota'iga uaea LAN tau feso'ota'iga
Uafu feso'ota'iga uaea WiFi uaealesi ua fausia i totonu (filifiliga)
Fa'atonuga ta'avale manatua 1G / 512M
Fa'atonuga fa'apipi'i 512M / 256M
Ole taimi ole mauaina o fa'amatalaga 250MHz / 80MHz
Alavai e iloa ai le Ultrasonic
Va'aiga fua 0-60mV
Va'aiga su'esu'e taimi 20~200kHz
Auala e iloa ai le UHF
Su'esu'eina taimi 300~1800MHz / 300~1500MHz
Va'aiga fua -80~10dBm
Sese ±1dBm
I'ugafono 1dBm
HFCT auala e iloa ai
Fa'asologa o taimi 0.5~100MHz
Sese ±1dB
Va'aiga malosi 60dB
Va'aiga fua 0-100mV
Sa'o 1dB
Auala e iloa ai le TEV
Fa'asologa o taimi 3~100MHz
Sese ± 1dB/mV
Ma'ale'ale 0.01mV
Va'aiga fua 0-60dB/mV
I'ugafono 1dBm/mV
Ma'a
Ma'a ua fausia i totonu Lithium maa, 12V, 4400mAh / Lithium maa, 12V, 2000mAh
Fa'aaoga le taimi e tusa ma le 8 itula / tusa ma le 6 itula
Taimi e fa'atumuina E tusa ma le 2 itula
Puipuiga maa Ova-voltage ma le ova-vave puipuiga
Totogiina maa
Fuafuaina voltage 12.6V
Totogiina o mea e maua i le taimi nei 2A
O le vevela o galuega -20℃-60℃
Susū galue <80%
GDPD-414H Tu'ulima fa'aaliga fa'aaliga (vaega fa'apisinisi)
PPU Intel Quad Core Atom Z3735F
GPU Intel HD Ata (Kene7)
moli 32GB
RAM 2GB
Faiga fa'agaioiga Windows10
Fa'aaliga 8.1 inisi 1280×800 IPS mata
Feso'ota'iga feso'ota'iga Wifi ma le Bluetooth
Ma'a 3.7V 8500mAH polymer lithium ion maa
Thinkpad Laptop po'o Tablet PC
Tele
Lapopo'a pusa fa'aoga / PD mauaina le tele o talimalo 395mm*295mm*105mm / 240mm*165mm*55mm
mamafa talimalo PD 3kg / 0.65kg
PD fa'a'au'au fa'alava lapoa / Fa'aali le tele fa'amau fa'amau 570mm*360mm*240mm / 395mm*295mm*105mm
Fa'aali le mamafa fa'amau fa'amau 0.85kg
Aofa'i pusa lapoa 570mm*360mm*240mm
Siosiomaga faigaluega
Galulue vevela -20℃~50℃
Susū o le siosiomaga 0~90%RH
tulaga IP 54

GDPD-414H U'ulima Vaega Fa'asa'oloto Su'esu'e

GDPD-414H-Handheld-Partial-Discharge-Detector1
GDPD-414H-Handheld-Partial-Discharge-Detector01
GDPD-414H-Handheld-Partial-Discharge-Detector
GDPD-414H-Handheld-Partial-Discharge-Detector2
GDPD-414H Handheld Partial Discharge Detector5
GDPD-414H Handheld Partial Discharge Detector4

  • Muamua:
  • Sosoo ai:

  • Auina mai lau savali ia i matou:

    Tusi lau savali iinei ma lafo mai ia i matou

    Auina mai lau savali ia i matou:

    Tusi lau savali iinei ma lafo mai ia i matou