GDZJ-30S Liliu-i-Liu Si'isi'i Tumau Su'ega
Volosa fa'aofi | 220V±5%;taimi 50/60Hz±2% |
Va'aiga fua | 0-30kV, fetuunaiga faifaipea, ±5% |
Taimi fa'aoso | 6.25 taimi/s - 50 taimi/s |
Taimi si'itia o galu | 0.1-0.5μS |
Fa'atonuga sese | (+0.3) / (-0.1) µs |
Uuna'i malosi | 0.01μF -0.1μF |
Malosi'i fa'aola | 60J |
Fa'aaogāga malosi | 1000VA |
Tete'e puipui | Insulation teteʻe i le va o le eletise e tuʻuina atu laina ma le suʻega ≥20MΩ |
Malosiaga dielectric | 1500V/50Hz i le 1min, e leai se moli ma malepe mo le faʻataʻitaʻiina o le suʻega voltage. |
vevela | 0-40 tikeri |
Susū fa'atusa | ≤80% i le 40 tikeri |
Vaveform capacitance deviation | ±3% |
Fua | 650*550*1700mm |
mamafa | 100kg |
Fa'atatauga | Liliu e fa'asaga i su'ega voltage mo le va'aiga 10kV afi |
Auina mai lau savali ia i matou:
Tusi lau savali iinei ma lafo mai ia i matou