GDYZ-301 Zinc Oxide Surge Arrester Suʻega
1. 800 * 480 lanu LCD mata pa'i, ma lomitusi vevela vevela maualuga.
2. Fa'aaliga ata, fa'aoga fa'aoga, faigofie ona fa'agaoioia ma fa'aoga i luga ole laiga.
3. Felauaiga uaea mamao mamao.PT signal wireless transmission mamao e sili atu i le 400m (2000m e mafai ona faʻapipiʻiina).
4. E talafeagai mo suʻega i tulaga eseese e pei o le uila puʻeina pe leai se eletise, falesuesue.
5. Faʻataʻitaʻi le tolu vaega o loʻo i ai nei, tolu vaega voltage i le taimi e tasi, sili atu ona lelei.
6. Leai se eletise malosi i totonu, voltage e le sili atu i le 12V.O le taimi nei ma le voltage sensors ua matua vavae ese, saogalemu ma faatuatuaina.
7. Lagolago eseese voltage sampling: 1. Uaea;2 uaealesi;3. Le-voltage;
A. Uaea: fa'asalalau fa'afuainumera fa'ailoga fa'atasi ma le uaea lea o le fa'ailoga e mai le PT mita fa'avili;
B. Uaealesi: fa'ailoga fa'akomepiuta fa'asalalauga uaealesi lea o le fa'ailo e mai le PT mita fa'avili;
C. Non-voltage: e le manaʻomia ona maua faʻailoga mai PT terminals.Fa'aoga le fa'atatauina o polokalame e maua ai le tulaga fa'a-volt.
8. Fausia-i le maualuga gafatia Li-maa, talafeagai mo le leai se fanua tuuina atu malosiaga.
9. Faʻaaogaina masini faʻapipiʻi faʻapipiʻi ma faʻaogaina faiga faʻaogaina, e mafai ona faʻalauteleina galuega faʻalogo leo ma vitio ma galuega faʻafiafiaga taʻaloga.
10. O le meafaigaluega e mafai ona sui i luga ma tape i soʻo se taimi, lea e sili atu le mautu nai lo le meafaigaluega ma komepiuta alamanuia e pei o meafaigaluega faʻavae, ma e le faigofie ona paʻu ma pa'ū faiga.
11. Fa'aauupegaina i se uafu USB e lagolago ai le auina atu i fafo o faʻamatalaga mai le U disk.
12. Fausia 4GB SD card, e mafai ona teuina faʻamatalaga suʻega tele, ma e iai galuega e pei o le puleaina o faʻamatalaga ma le teuina.
13. Saosaoa maualuga fa'ata'ita'iga taimi, fa'aonaponei fa'atekonolosi fa'ailoga fa'ailoga, malosi malosi fa'alavelave fa'alavelave, maualuga fa'ai'uga fua.
14. Faʻatasi ai ma le pefu-faʻamaonia, leai se vai, pusa faʻamaufaʻailoga palasitika anti-corrosion, laʻititi laʻititi, mama mama, faigofie ona ave.
1. Sapalai Malosiaga
Lagolago fa'afeso'ota'i eletise i fafo (12V/2A) ma le fa'aogaina o le eletise i totonu;
2. Fua fua
Leakage Current (RMS) 0-10mA (scalable);
Malosi (RMS) 30-100V (mafai fua).
3. Fuaina sa'o
Le taimi nei: aofa'i atoa> 100μA, ± 2% o le faitau ± 1numera;
Voltage: Fa'asinoga voltage fa'ailoga> 30V
Uaea: ± 2% o le faitau ± 1numera;
Uaealesi: ± 5% o le faitau ± 1numera;
4. Fua fa'atatau
Leakage o lo'o i ai nei le aofa'i o galu, fa'avae galu RMS, tau maualuga.
Fa'asagaga vaega fa'avae galu RMS o le leakage, 3, 5, 7 taimi RMS.
Resistive vaega taua pito i luga o le leakage i le taimi nei, e aofia ai le tau maualuga lelei Ir +, tau maualuga le lelei Ir-.
Capacitive galu fa'avae i le taimi nei, voluma atoa, ese'esega tulimanu vaega atoa.
Malolosi RMS.
Fa'aaogāga malosi ole fa'apalapala.
5. Fa'asinoala alavai faailoilo fa'ata'ita'iga
Fa'amaopoopo uaea: 20m (e mafai ona fa'alautele);
Fa'amaopoopo uaealesi: >400m (e mafai ona fa'alautele);
6. Parakalafa maa
Taimi fa'atumu> 6 itula
Taimi galue faifai pea> 4 itula
Taimi faigaluega fa'afuase'i > 8 itula
7. Fua:360*260*140mm (Tali'i);420 * 330 * 200mm (Mata faaopoopo);
8. mamafa:5kg (Tagata talimalo);9kg (Pusa fa'aoga);
Ata 1 Vaega Talimalo
1. Uafu fa'avae 2. 0-2mA fa'aoga o lo'o i ai nei 3. 2-10mA fa'aoga o lo'o iai nei.
4. Antenna sucker 5. Uaea synchronization taulaga 6. Uaea synchronization taulaga
7. faamau ON/OFF 8. Taulaga tau 9. Faailoga faailo
10. Fa'ailoga malosi 11. Fa'aili 12. Fa'aoga USB 13. Pa'i lanu mata LCD 14. Lomitusi
Ata 2 PT Voltage Emitter
1. ON/OFF faamau 2. Uafu fa'atumu 3. Fa'ailoga eletise
4. Antenna sucker 5. Faailoga faailo 6. Antenna uafu
7. Fa'alaloina uafu 8. Tau feso'ota'iga i le va o le talimalo ma le PT voltage emitter 9. PT voltage input
Talimalo | 1pc |
Pusa fa'aopoopo | 1pc |
PT eletise eletise | 1pc |
Uaea su'ega o iai nei | 3pcs |
Uaea su'ega volta | 1pc |
Uaea eleele | 2pcs |
Fesootaigauaea | 1pc |
Antenna | 2pcs |
Totogi | 2pcs |
Lomi pepa | 2 taaiga |
Tagata fa'aoga'smtausaga | 1pc |
Lipoti o su'ega | 1pc |