GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator)

GDW-102 Oil Dew Point Tester (Coulometric Karl Fischer Titrator)

Brief Description:

Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology.


Product Detail

Product Tags

Coulometric Karl Fischer technology is applied to measure precisely trace moisture the measured sample contains.The technology is widely used for accuracy and cheap test cost.The Model GDW-102 measure precisely trace moisture on liquid, solid and gas samples according to the technology. It's used in electricity, petroleum, chemicals, foods and so on.

Features

Use improved PWM electrolysis circuit to reduce the power dissipation of the instrument.
High precise measuring electrode signal and circuit detection make the electrolytic end decision quickly and precisely with strong anti-interference ability.
Use methods of electrolyte blank current compensation and electrolyte balance drift compensation to devise testing result.
Built in three calculation formula to generate report automatically.
The buttons regulating mixing speed have ten speeds(0~9speed).
Measure electrode open-circuit fault and short circuit fault automatically.
It can store 256 history records with time.
Calender clock with temperature can automatically store testing date and time accurately, which can work 10 years above with power down.
When the instrument does not work for long time, the LCD screen will shut down automatically to protect the screen and last the screen life. Press any buttons to quit the screen protection.
There is RS232 interface to connect with PC and mini-printer easily.

Specification

Electrolysis current

Max.400mA

Max electrolysis speed

Max.2.4mg/min

Measuring range

10ug100mg  

Sensitivity

0.1ug

Precision

±3ug for 10ug1mg     

RSD 0.3% or less for 1mg or more

Ambient Temperature

535

Ambient humidity

≤85% RH

Power Supply

AC220V±20% 50HZ±10% ,40VA

Dimensions

 270×210×125(mm)

Weight

5kg

Maximum power consumption

30W

Accessories
Main unit 1 piece
Electrolysis electrode 1 piece
Measurement electrode 1 piece
Stirring nut 2 pcs
Silica gel particle 1 piece
Silica gel mat 10 pcs
0.5μl Sample injector 1 piece
50μl Sample injector 1 piece
1ml Sample injector 1 piece
Drying tube 1 piece
Power cord 1 piece
Vacuum grease 1 piece
Electrolyte 1 piece
User's guide 1 copy
Factory test report 1 copy

  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us