GDPD-306M Portable Ultrasonic Partial Discharge Detector
GDPD-306M o loʻo faʻaaogaina lautele i le faʻaogaina o le faʻaogaina o vaega ole eletise.E aofia ai le eletise eletise maualuga, mama mama, voltage / transformer i le taimi nei, transformer (aofia ai le transformer ituaiga mago), GIS, laina i luga o le ulu, uaea, ma isi mea faʻapipiʻi tulaga tulaga iloa.
O fa'ailoga nei o lo'o fa'aogaina e fua ai le maualuga o le tu'uina atu o masini eletise:
Su'esu'eina o le malosi o le fa'asao: E ala i le fuaina o le fa'ailo fa'amalo i se ta'amilosaga fa'asolosolo eletise, o le malosi o le fa'amatu'u fa'apitoa e fa'aalia e tusa ai ma le maualuga o le tau (dB) i le fa'asologa o le pulusua.
Su'esu'eina taimi fa'asa'o: E fuaina e le masini le fa'ailo fa'amalo i totonu o le ta'amilosaga o le eletise, fa'ate'a fa'asolo ma fa'ailoa mai le tele o fa'ama'i fa'ate'a e tusa ai ma le aofa'i o fa'agasolo.
●Faatasi ai ma sensors eseese e ausia vaega lafoaia iloa toetoe o meafaigaluega eletise uma.
●Tuuina atu le tele o faʻataʻitaʻiga e pei o le taimi-domain waveform, PRPD, PRPS, ma isi, e iloa ai le suʻesuʻeina o ituaiga faʻasalalau eseese.
●Fa'aoga-tagata fa'aoga-masini fa'afaigofieina le puleaina o fa'amatalaga o masini eseese, e aofia ai le traceability o suiga o fa'amaumauga fa'asolopito, fa'ata'ita'iga fa'ata'ita'iga ma tu'usa'o, ma iloa ai le 360° su'esu'ega atoatoa o le masini su'esu'e.
●O lo'o fausia i totonu o le ultrasonic sensor ma le le tumau o le eletise eletise (lea e ta'ua mulimuli ane o le TEV), e mafai foi ona fesoʻotaʻi i fafo faʻapitoa faʻapitoa mo transformers, GIS, laina i luga, ma uaea.
●E faʻaaogaina auala e le faʻafefe ai, e leai se manaʻoga e paʻu i le taimi o le suʻega, e leai se manaʻoga e faʻapipiʻi le puna eletise maualuga, e sili atu ona faigofie le faʻaogaina nai lo le faʻaogaina o le tuʻufaʻatasiga faʻapitoa.
●Ole fua ole bandwidth ole su'ega ole 30kHz ~ 2.0GHz, e talafeagai mo le su'esu'eina o mataupu faavae o laina ole tele.
Fuaina TEV | Fua UHF | ||
Fualautele | 0-60dBmV | Su'e alavai fa'aili | 300~1500MHz |
I'ugafono | 1dB | Va'aiga fua | -75-0dBmV |
Sa'o | ±1dB | Sa'o | <1dBmV |
Max. fatu i le taamilosaga | 1400 | Fa'ailoga fa'alava fa'alava | 300-2000MHz |
Fuaina o alaleo ala | 1~100MHz | ||
fua AA | Fua AE | ||
Va'aiga fua | -6dBμV~68dBμV | Va'aiga fua | -6dBμV~68dBμV |
I'ugafono | 1dB | I'ugafono | 1dB |
Sa'o | ±1dB | Sa'o | ±1dB |
Sauniga nofoaga tutotonu | 40kHz | Fa'asologa o taimi | 40-200kHz |
Su'ega HFCT | |||
Fa'aletonu le fa'aulufaleina o masini | 5mV/mA | ||
Su'esu'e taimi | 1~30MHz | ||
Ma'ale'ale | ≤50pC | ||
Meafaigaluega | |||
Atigi | ABS | ||
Faaalia | 4.0inisi RGB LCD mata | ||
Controller | ARM | ||
Feso'ota'i | fa'aoga USB (taulaga fa'atumu), WIFI uaealesi 3.5mm leo leo headphone jack, Fa'ailoga fa'asologa o feso'ota'iga uaea Fa'aulufale masini fa'afofoga ultrasonic | ||
Fa'alogo | 8ohm laʻititi | ||
SD card | Tulaga 16G | ||
Ma'a ua fausia i totonu | 3.7V/1Ah maa lithium | ||
Taimi faigaluega | E uiga i8itula | ||
Totogi | AC 90-264V po'o DC 5V | ||
Galulue vevela | -20~+50℃ | ||
Susū | 20~85% susū fa'atatau | ||
Fua, mamafa | 210*100*35(mm), 0.4kg (iunite autu) |
Vaega autu | 1 | Standard |
External Fa'afeso'ota'i le masini ultrasonic | 1 | Fpoʻo le filifiliga, faʻaaogaina mo transformers, GIS, afi |
UHF fa'alogo | 1 | Fpo'o le filifiliga, fa'aoga mo le GIS |
HFCT | 1 | Fpo'o le filifiliga, fa'aoga mo le uaea eletise |
Tuaea | 1 | Standard |
Charger | 1 | Standard |
uaea USB | 1 | Fpo'o le fa'atonuina ma feso'ota'iga PC |
Utaiala a ser | 1 | |
Flipoti su'ega tala faatino | 1 |