GDOT-3B 100kV Tolu Ipu Insulation Suau'u malepelepe Voltage (BDV) Su'ega

GDOT-3B 100kV Tolu Ipu Insulation Suau'u malepelepe Voltage (BDV) Su'ega

Fa'amatalaga Puupuu:

GDOT-3B e ave se masini komepiuta e tasi e fai ma autu, e iloa uma le masini suʻega, maualuga le saʻo o fua, faʻaleleia atili le lelei o galuega, ma faʻaitiitia ai foi le malosi o le aufaigaluega.

 


Fa'amatalaga Oloa

Faailoga o oloa

Tulaga

IEC 156: 1995 Suavai faʻapipiʻi - Fuafuaga o le malepelepe eletise i taimi ole eletise

Vaega

Faʻaaogaina se microprocessor, tolu ipu i le tasi, ma faʻamaeʻa faʻamaeʻaina le gaioiga o le faʻamalosia, uuina, faʻamalosi, tu, faʻatusatusaina, lolomi, ma isi, ma mafai ona faʻatautaia le suauʻu faʻafefeteina suʻega voltage i le va o le 0-100kV.
fa'aaliga mata LCD.
O le faʻaogaina o lenei meafaigaluega e faigofie, naʻo le tagata faʻapitoa e manaʻomia le faia o ni faʻaoga faigofie, ma o le meafaigaluega o le a otometi lava ona faʻamaeʻaina le suʻega o 1-3 suauʻu faʻataʻitaʻiga e tusa ai ma tulaga.Mo faʻataʻitaʻiga suauʻu taʻitasi, e otometi lava ona teuina le tau o le voltage malepe ma le numera o taamilosaga.A mae'a le su'ega, e mafai e le lomitusi fa'avevela ona lolomi i fafo le tau malepelepe male tau averesi o fa'ata'ita'iga suau'u ta'itasi.
Taofi le paoa, e mafai ona teuina 100 fa'ai'uga o su'ega, ma mafai ona fa'aalia le vevela ma le susū o lo'o iai nei.
E faʻaaogaina le microcomputer pulea e tasi mo le faʻaleleia o le saoasaoa, ma le voltagee sa'o le taimi i le 50Hz, e faigofie ai ona pulea le faagasologa atoa.
Faatasi ai ma le tele-voltage, faʻatapulaʻa o loʻo iai nei ma isi puipuiga e faʻamautinoa ai le saogalemu o tagata faʻatautaia.
Fa'atasi ai ma fa'aaliga fa'aalia le fuaina o le vevela ma fa'aaliga uati faiga.
Standard RS232 interface, e mafai ona fesootai ma komepiuta.

Fa'amatalaga

Volosa gaosi

0-100kV faitalia

Fa'aletonu le malosi

<3%

Voltage fa'ateleina le saoasaoa

0.5~5kV/s fetuutuunai

Faaalia

Mata tele LCD

Va'a eletise

tulaga masani 2.5mm

Faʻateleina taimi

1~10 taimi

Taimi tu

15 min (fa'atonu)

Fa'ateleina le va

5 minute (fa'atonu)

Fa'aola malosi

1.5kVA

Sa'o le fua

±3%

Malosiaga tuu

AC220V± 10%, 50Hz±1Hz

Malosiaga

200W

Galulue vevela

0-45 ℃

Susū

<75%RH

Fua

585mm * 390mm * 410mm

mamafa

43kg

Mea fa'aoga
GDOT-3B Su'e 1 seti
Ipu suauu 3 pc
Uaea eletise
1 pc
Uaea eleele 1 pc
Fuse fa'asao 2 pcs
Fa'asao nati 2 pcs
Fua masani 2.5mm 1 pc
Tweezer 1 pc
Lomi pepa 1 taaiga
Allen wrench 1 pc
Ta'iala a le tagata fa'aoga 1 pc
Lipoti su'ega falegaosimea 1 pc