GDKC-15 Fa'asologa Va'ava'ava'a Su'esu'ega
High voltage circuit breaker o se tasi lea o mea e sili ona taua e pulea ai le eletise.GDKC-15 Fa'asologa o lo'o fa'aaogaina e fa'ata'ita'i ai uiga fa'amalosi o le va'ava'a eletise eletise maualuga.E faigofie ona faʻaogaina, ma maualuga le saʻo.
GDKC-15A | GDKC-15B | GDKC-15C | GDKC-15D | GDKC-15E | GDKC-15F | GDKC-15G | GDKC-15H | |
Feso'ota'iga u'amea | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
Tapuni tetee | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
Feso'ota'iga kalafi | 3 | 3 | 3 | 3 | 6 | |||
Fa'avae fa'ai'u fa'alua | 3 | 3 | 3 | 6 | ||||
Tete'e fa'aola | 1 | 1 | 3 | 3 | 3 | 3 | 6 | |
Tete'e tumau | 1 | 1 | 3 | 3 | 3 | 3 | 6 | |
Tete'e i le eleele | 3 | 6 |
●E fetaui lelei mo le suʻega faʻainisinia o ituaiga uma o SF6 sui, GIS tuʻufaʻatasiga meafaigaluega, vacuum switch ma suauʻu suauʻu.
●Malosi fa'alavelave fa'alavelave.E mafai ona faigofie ona tofotofoina ma saʻo fuaina i le 500KV substation.
●Accelerometer (filifiliga), laina laina, rotary sensor, faigofie ona faʻapipiʻi ma faigofie.
●O fa'amaumauga uma o le su'ega o uiga fa'ainisinia ma le fa'afanua fa'atusa e maua mai pe a uma ona fa'atino le ki e tasi.
●Teu le faʻamaumauga o suʻega fanua ma fausia-i totonu o le taimi moni uati, lea e faigofie mo le teuina ma sefe le aso ma le taimi o le suʻega.
●Fa'atasi ai ma le 10.1inch LCD mata, fa'aali uma fa'amatalaga ma fa'afanua, fa'atasi ai ma le malamalama i tua, LCD fetu'una'iga fa'atusatusaga ma fa'amalo le manatua.
●Fa'agaioiga lisi fa'auo, faigofie ona fa'aoga.Fa'atasi ai ma lomitusi fau-i totonu e lolomi vave ai fa'amaumauga uma.
●Fa'aauupegaina i fa'amaumauga o fa'amatalaga fa'atonu polokalame, lea e mafai ona fa'agaioia i luga o le initaneti ma le PC, fa'atasi ai ma faila faila WORD.O fa'ai'uga o su'ega e mafai ona tu'uina atu i ituaiga uma o lomitusi lolomi lipoti su'ega ina ia fa'akomepiuta le su'ega fanua.
●Tatala ma tapuni le saoasaoa o filifiliga ma le tagata e faʻaogaina galuega faʻatulagaina e tusa ai ma manaʻoga, talafeagai mo le fuaina o le saoasaoa o soʻo se ituaiga suiga.
●Taimi:
12 feso'ota'iga o lo'o iai le taimi tatala (tapuni).
I le vaega o le synchronization
Fa'asoa fa'atasi i lea vaega
●Toe tapuni:
CO, OC, COC taimi,
Taimi tatala muamua, taimi tapuni muamua, tapuni lona lua, tapuni tapuni, taimi mate, leai se taimi nei.
●Pa'u:
Tapuni le taimi, taimi, fa'agaioiga ma fa'agaioiga o feso'ota'iga ta'itasi.
Tatala fa'aola fa'aola o feso'ota'iga ta'itasi.
Velocity: saosaoa i fesoʻotaʻiga naʻo le tatalaina ma naʻo le tapunia, maualuga le saoasaoa, taimi-malaga uiga piʻo.
Malaga: malaga atoa, mamao matala, i luga o femalagaaiga, alu i luga ole malaga, toe faʻaleleia amplitude.
Ole taimi nei: tatala/tapuni le taimi nei, fa'asologa o galu o lo'o i ai nei o le coil tatala/tapuni.
Galulue eletise: fausia-i DC0 ~ 300V/20A numera, fetuutuunai puna mana o le breaker, otometi maeʻa LV suʻega gaioiga o le vaeluaga o le matagaluega ma fua le tau voluma gaoioiga o breaker.
Tapuni tete'e: muai lafo taimi, muai-pitch waveform ma le taua tetee o le tetee tapunia o 6contacts.(filifiliga)
Fa'afeso'ota'i graphite: o le taimi tatala, tapuni ma fa'agaioiga fa'agaioiga o le ki fa'afeso'ota'i Siemens graphite fa'atasi ma feso'ota'iga 3 po'o 6-ala.(filifiliga)
Fa'avae fa'alua fa'ai'u: lalo ole 3 po'o le 6-auala lua-taulaga fa'avae, e mafai ona fua sa'o le taimi tatala ma tapuni.(filifiliga)
Tete'e tumau: 1*100A fua fa'afeso'ota'i.
Tete'e malosi (Pre-insertion resistor): 1*100A suiga galu o le malosi tete'e i le taimi o gaoioiga breaker.
●Fa'aoga Siosiomaga
Malosiaga Fa'aulu: 220V±10%, 50Hz±10%, Va'aiga o le Ea: 86-106kpa
Vevela: -10-40 ℃ Susū: ≤80% RH
●Fa'atinoga o le Saogalemu
Insulation Resistance>2MΩ
Malosiaga Dielectric: Shell e mafai ona tetee atu i le eletise eletise 1.5kV i le 1 minute e aunoa ma le flashover ma le faʻailoga.
●O Fa'avae Autu
Taimi: Va'aiga 20000.0ms, iugafono 0.01ms, sese 0.5%
Tapuni tetee: vaeluaga 10kΩ, min.iugafono 1Ω, sese 0.5% (filifiliga)
Feso'ota'iga kalafi: va'aiga 200ms, min.iugafono 0.1ms, sese 0.5% (filifiliga)
Fa'avae fa'ai'u fa'alua: va'aiga 200ms, min.iugafono 0.1ms, sese 0.5% (filifiliga)
Tete'e tumau: va'aiga 1uΩ~10mΩ, min.iugafono 0.01μΩ, sese 0.5%
Tete'e malosi: va'aiga 10mΩ, min.iugafono 1μΩ, sese 0.5%
Su'ega o lo'o iai nei: DC 50A, 100A (3 vaega fuaina i le taimi e tasi)
Saosaoa: Va'aiga 20.00m/s iugafono 0.01m/s sese 0.5%
Malaga:
Ituaiga | Avanoa | I'ugafono | Sese |
Vacuum break | 50.0mm | 0.1mm |
0.5% |
SF6 va'ava'a ta'avale | 300.0mm |
1mm | |
Suauuva'a ta'avale | 600.0mm |
Le taimi nei: va'aiga 20.00A, iugafono 0.01A
Mana fa'aoso: DC 0-300V numera fetu'una'i/20A (galue vave), iugafono 1V.
Fua: tusa 360mm (L)* 280mm (W)* 300mm (H)
Mamafa: e tusa ma le 10kg
Autuunit ma le 10.1-inisi papalama | 1 ituc |
Pusa fa'aopoopo | 1 pc |
Totogi mo le laulau | 1 pc |
American standard adapter | 2 pcs |
Rotary saosaoa sensor | 1 pc |
Saosaoa fa'ailo laina50mm | 1 pc |
Uaea feso'ota'iga fa'ailo saoasaoa (5-uaea talipupuni autu) | 1 pc |
Tatala ma tapuni uaea pule(3-uaea faaofuofu autu) | 1 pc |
Fa'aoso fafoiloauaea (mumu/uliuli, 2-core) | 1 pc |
Uaea eleele | 1 pc |
Fa'afeso'ota'i uaea su'ega(4-uaea faaofuofu autu) | 1pc |
Cuaea fa'alautele su'ega fa'atasi (5M, samasama, lanu meamata ma le mumu ta'itasi, uliuli 3pcs) | 6pcs |
Uaea pupuu (0.5m uliuli,2m uliuli) | 2 pcs |
Uaea eletise | 1 pc |
So'o fa'atasi ma fa'avae maneta | 1 seti |
Mea fa'apipi'i fa'apipi'i fa'apitoa | 1 seti |
Fa'ata'ita'i kilipa ma fa'amau | 18 pcs |
Cuaea su'ega ontact resistance(5M) | 1 pc |
Lomi pepa | 2 taaiga |
uaea USB | 1 pc |
Ta'iala a le tagata fa'aoga | 1 pc |
Lipoti su'ega falegaosimea | 1 pc |