GDCR3200C Double Clamp Multifunctional Earth Resistance Tester ua mamanuina faapitoa ma gaosia mo le fuaina o le eleele i luga o le saite, le tetee o le eleele, le eletise o le eleele, le tafe o le laina eletise, AC ma le DC tetee.O le meafaigaluega e faʻaaogaina tekinolosi faʻaogaina numera, faʻatasi ai ma le 2-wire method, 3-wire method, 4-wire method, auala filifilia, faʻalua faʻapipiʻi auala ma isi metotia fua;Fa'aulufaleina mai le FFT (Fast Fourier Transform), tekinolosi AFC (Automatic Frequency Control), faʻatasi ai ma le tulaga ese o le faʻalavelave faʻalavelave ma le faʻaogaina o le siosiomaga, maualuga le faʻaauau o suʻega, faʻamautinoa le maualuga o le saʻo, maualuga le mautu ma le maualuga o le faʻatuatuaina mo fua umi. lapo'a lapo'a lapo'a o lo'o i ai nei, e mafai ona feagai ma ituaiga uma o mana'oga o su'ega, e mafai ona fuaina le tau o le fa'amauina o le fa'amauina o le tele o le ta'ita'i, fetuutuuna'i le fuaina o le tau o le fa'amauina o le mata'itusi tasi ma le fa'avasegaina o le eleele ma ituaiga uma o fausaga fa'avae lavelave, e leai se mana'oga e motusia so'o se feso'ota'iga tutusa pole eleele pe a fuaina faiga fa'avae tutusa, fa'aleleia atili le fa'aogaina o le fuaina, aua o le su'ega fa'atinoina o le eleele e maua ai se fofo atoatoa.
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester o loʻo aofia ai masini talimalo, faʻapipiʻi o loʻo i ai nei (faalua faʻalua), uaea faʻataʻitaʻi, tootoo faʻapipiʻi fesoasoani, polokalama faʻamatalaga ma uaea fesoʻotaʻiga ma isi.Le tele LCD faʻaaliga o masini talimalo ma backlight paʻepaʻe ma faʻailoga kalafi pa e mafai ona iloa manino.O loʻo i ai i le suʻega galuega faʻapipiʻi, galuega o le uati, ma otometi lava ona teuina 2000 vaega o faʻaiʻuga o suʻega o loʻo i ai le aso ma le taimi. O le suʻega faʻatasi ai ma le fesoʻotaʻiga Bluetooth e lagolagoina le polokalama Android.A maeʻa le faʻapipiʻiina o le APP, e mafai ona faʻataʻitaʻi pe faitau faʻamaumauga suʻega i le telefoni feaveaʻi, aumaia se poto masani fou.E fa'aauupegaina e le su'ega fa'aoga USB, ma o fa'amaumauga o lo'o teuina e mafai ona tu'uina atu i le PC e ala i le fa'aoga USB.E mafai e le polokalame fesoʻotaʻiga ona iloa galuega o le faitau, faʻatalanoa, faʻasaoina, lipoti ma le lolomiina o faʻamaumauga faʻasolopito.Fa'aaoga lautele i le malosi, feso'ota'iga, meteorology, suau'u fanua, fausiaina, puipuiga uila ma mea tau eletise.
●Fuafuaga tulaga ese o le moli faailoilo jack, faʻailoga saʻo o le tulaga jack, aloese mai mea sese.
●O le fa'aogaina o le kivi filifiliga, o metotia su'ega eseese o lo'o fa'aalia, fa'afaigofie ma vave le ta'aloga.
●O le su'ega o lo'o i ai feso'ota'iga feso'ota'iga Bluetooth ma lagolagoina le polokalama Android.E mafai e tagata fa'aoga ona fa'aoga telefoni feavea'i e fa'ata'ita'i ai le fa'agaioiga po'o le faitau fa'ai'uga o su'ega o lo'o iai le aso ma le taimi ma le faigofie.
●O le pusa meafaigaluega e faʻaaogaina ai le pusa puipuia e le susu, e malosi, saogalemu ma umi mo le faʻalavelave faʻafefe, anti-pa'ū ma le susu (puipuiga IP65), aemaise lava mo le faʻaogaina i nofoaga faufale i fafo.
●O lo'o fa'apipi'iina le mita i le pusa maa lithium e mafai ona fa'aaogaina.Ma faʻatasi ai ma faʻaoga USB e faʻapipiʻi ai galuega faʻamaumauga.
Tulaga autu & Tulaga o Galuega
Fa'aa'afiaga Tele | Tulaga Faavae | Tulaga Galuega | Fa'amatalaga |
Ambient Temp | 23℃±1℃ | -10℃-40℃ | ---- |
Susū Ambient | 40%-60% | <80% | ---- |
Galulue Voltage | 7.8V±0.1V | DC 7.8V±0.6V | ---- |
Auxiliary Earth Resistance | <100Ω | <5kΩ | |
Galulue Fa'alavelave | E tatau ona aloese | <20V | |
Fa'alavelave i le taimi nei | E tatau ona aloese | <2A | |
Electrode Mamao pe a fua R | a>5d | a>5d | |
Electrode Mamao pe a fua ρ | a>20h | a>20h |
Fa'amatalaga lautele
Galuega | Fua le tete'e o le eleele, le tetee o le eleele;DC tete'e, eletise eleele, alternating current , leakage le taimi nei | |
Paoa sapalai | DC 7.4V 2600mAh maa lithium rechargeable, tumu i le 8.4V | |
Molī tua | E mafai ona fa'atonutonuina le moli i tua, e talafeagai mo nofoaga fa'alilolilo | |
Metotia Fua | DC tetee | DC tetee 2-uaea auala |
DC tetee 4-uaea auala | ||
Tete'e o le eleele | Tete'e o le eleele 2-uaea auala | |
Tete'e eleele 3-uaea auala | ||
Tete'e o le eleele 4-uaea auala | ||
Fa'asagaga o le eleele pipii tasi auala 3-uaea (auala filifilia) | ||
Fa'asagaga o le eleele pipii tasi auala 4-uaea (auala filifilia) | ||
Tete'e eleele double auala pipii | ||
Tete'e o le eleele(Wenner method) | ||
Fa'alelalolagi | Fuaga pipii o iai nei | |
Malosiaga eleele | Fa'asa'o masani | |
Su'ega Galu Galu | Galu o le Sina | |
Su'ega Fa'atele | 128Hz/111Hz/105Hz/94Hz(AFC) | |
Fa'ata'ita'iga Fa'ata'ita'i Pu'upu'u | AC 250mA maualuga | |
Su'ega va'ava'ava'a i le taimi nei | AC 40V maualuga | |
Electrode Va'aiga mamao | 1m-100m | |
Fa'aaliga Fa'aaliga | 4-numera tele LCD faʻaaliga, faʻatasi ai ma le moli tua | |
Fua Faailoga | I le taimi o fuataga, faʻaalia moli moli, faʻaaliga LCD countdown | |
Fua Fa'avaa LCD | 128mm×75mm | |
nofoaga fa'aali LCD | 124mm×67mm | |
Fua o Meafaigaluega | 280mm(L) X 260mm(W) X 160mm(H) | |
CT Tele | 223mm X 120mm X 39mm | |
Uaea Su'ega | 4 uaea: ta'itasi mo mumu 20m, uliuli 20m, samasama 10m, ma lanumeamata 10m | |
Uaea Su'ega Faigofie | 2 uaea: ta'itasi mo mumu 1.6m ma uliuli 1.6m | |
Auxiliary Grounding Rod | 4PCS: Φ10mm X150mm | |
Pi'i o lo'o iai nei | 2PCS :1 pulu lanumoana-uliuli ma 1 mumu-uliuli palaka | |
Fa'amau Caliber | Φ70mm | |
U'u Uea Uea | 2m | |
Fua Faatatau | AC i le taimi nei: e tusa ma le 2 taimi / sekone | |
Malosi o le Lalolagi: e tusa ma le 2 taimi / sekone | ||
Tete'e o le lalolagi: e tusa ma le 7 sekone/taimi | ||
Fuaina Taimi | E sili atu i le 5000 taimi (Su'ega pu'upu'u, taimi vaelua e tatau ona le itiiti ifo i le 30 sekone) | |
Laina Galu | Fua i lalo ole AC 600V | |
Feso'ota'iga Feso'ota'iga | Bluetooth module, USB interface, teuina faamatalaga e mafai ona uploaded i komepiuta, faasaoina pe lolomi. | |
Uaea Fesootaiga | USB feso'ota'iga uaea x1pcs, ma le umi 1.5m | |
Taofi Faamatalaga | Fa'amatalaga taofi galuega: "TASI" fa'aaliga fa'ailoga | |
Teuina o Faamatalaga | 2000 vaega, "MEM" faailoga teuina, "FULL" faailoga moli moli teuina ua tumu | |
Avanoa Fa'amatalaga | Fa'amatalaga faitau galuega: "FAITAU" fa'aaliga fa'ailoga | |
Fa'aaliga Ova | Ova le fuaina o le tele o galuega fa'afefe: "OL" fa'aaliga fa'atusa | |
Fa'ailoga maualalo o lo'o iai nei | Fua i le auala filifilia poʻo le faʻapipiʻi faʻalua, o le faailo o loʻo maua e le CT2 e maualalo ifo nai lo le 0.5mA, o le a faʻaalia" ", ma e tatau ona siaki le itu faʻapipiʻi o le CT2 faʻapipiʻi nei. | |
Su'ega Fa'alavelave | Fa'ailoaina otometi o fa'ailoga fa'alavelave, fa'ailoga "NOISE" pe a maualuga atu le voltage fa'alavelave nai lo le 5V | |
Su'ega Fa'avae Ausilali | Fa'atasi ai ma galuega fa'ata'ita'i fa'avae fesoasoani, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ) | |
Galuega Fa'ailoga | O le fuaina o le tau e sili atu i le tau o le fa'ailo, o le a fa'aalia ai le leo fa'ailo "Toot-toot-toot". | |
Malosi o le ma'a | A'o fa'aitiitia le malosi o le maa i le 7.2V±0.1V, o le a fa'aalia ai le fa'ailoga maualalo o le maa, ma fa'amanatu e sui le maa. | |
Tapuni otometi | Tapuni otometi pe a uma le 15 minute o le eletise | |
Galuega i le taimi nei | Moli i tua: 25mA Max (na'o le fa'aogaina o le eletise) | |
Taofi: 25mA Max (Pepe le moli tua pe a uma le eletise) | ||
Fua: 150mA Max (Tapuni moli tua) | ||
mamafa | Su'ega: 2290g | |
Pi'u nei:1100g(2pcs) | ||
Aofaʻi mamafa: 6800g (aofia ai mea faʻaoga uma) | ||
Galulue Vevela & Susū | -10 ℃-40 ℃, i lalo ole 80%rh | |
Teuga vevela & susū | -20 ℃-60 ℃, i lalo ole 70%rh | |
Puipuiga Tulaga | IP65(tapuni le pusa) | |
Puipuiga ovata | Fua le tetee o le eleele: i le va o fesoʻotaʻiga taʻitasi o C(H)-E,P(S)-ES, AC 280V/3 sekone | |
Insulation Resistance | E sili atu i le 20MΩ (i le va o le taamilosaga ma fafo o atigi e 500V) | |
Malosiaga Malolo | AC 3700V/rms.(I le va o le taamilosaga ma le atigi fafo) | |
Fa'ailoga Electromagnetic | IEC61326(EMC) | |
Ituaiga Puipuiga | IEC61010-1(CAT Ⅲ 300V,CAT IV 150V,Filogia 2); IEC61010-031; IEC61557-1(tete'e o le lalolagi); IEC61557-5(Soil resistance); JJG 366-2004(Mata tete'e eleele) JJG 1054-2009(Mata tete'e fa'avae pipi'i) |