GDC-9560B Power System Insulation Suau'u Gas Chromatograph Analyzer
GDC-9560B Gas Chromatograph Analyzer o le suʻeina lea o le kesi o loʻo i totonu o le suauʻu faʻafefe e ala i le kesi chromatographic metotia.E aoga tele le fa'amasinoina pe iai ni fa'aletonu e pei o le vevela tele, fa'amalo pe leai, ina ia mautinoa le saogalemu o le eletise.E mana'omia fo'i le fa'aoga mo le gaosiga o masini kesi/suau'u e asiasia a latou mea faigaluega a'o le'i tu'ua le fale gaosimea.
Fa'atekonolosi su'esu'ega chromatography gas o se metotia mo le tu'ueseeseina ma le au'ili'iliga o fa'afefiloiga fa'aopoopo.E masani ona faʻaaogaina le eseesega o le faʻafefeteina, polarity ma le adsorption coefficient o vaega taʻitasi i le faʻataʻitaʻiga i le koluma, ina ia vavaeeseina vaega i le koluma, ma o vaega vavaeese e qualitatively ma quantitatively auiliiliga.
O le gas chromatograph e fa'aaogaina se kesi e fai ma vaega feavea'i (carrier gas).Pe a auina atu le faataitaiga i le injector ma vaporized, e tauaveina e le kesi feaveai i totonu o le koluma tumu po o capillary koluma ona o le mea e vela, polarity ma adsorption coefficient o vaega taitasi i le faataitaiga.O le eseesega o le vavaeeseina lea o vaega i totonu o le koluma, ona faʻasolosolo faʻasolosolo ai lea o faʻamatalaga e fesoʻotaʻi atu i le koluma e tusa ai ma uiga faʻapitoa o vaega, ma mulimuli ane o faʻailoga eletise liliu mai e auina atu i le fale faigaluega chromatographic.O le kesi chromatogram o vaega ta'itasi e fa'amaumauina ma au'ili'ili e se fale faigaluega chromatographic e maua ai fa'ai'uga au'ili'ili o vaega ta'itasi.
●E faʻaaogaina le 10/100M adaptive Ethernet fesoʻotaʻiga fesoʻotaʻiga ma fausia-i totonu o le IP protocol stack, lea e mafai ai e le meafaigaluega ona faigofie ona iloa faʻamatalaga mamao mamao e ala i le LAN i totonu ma le Initaneti.E faafaigofie ai le setiina o le falesuesue ma faafaigofie le falesuesue.O le faʻatulagaga e faʻafaigofie ai le puleaina o faʻamatalaga auʻiliʻili.
●Fuafuaga o faiga fa'afeso'ota'i tuto'atasi 3.E mafai ona faʻafesoʻotaʻi ma le gaioiga faʻapitonuʻu (laboratory), sili atu ona faigofie mo supavaisa e mataʻituina le tulaga o le taʻavale ma auʻiliʻili iuga.
●Ole fale faigaluega ole NetChromTM e mafai i le taimi e tasi ona lagolagoina le tele o chromatographs mo le faʻaogaina ma le faʻatonutonuina o faʻamaumauga, faʻafaigofieina le puleaina o pepa ma faʻaitiitia le faʻafaigaluegaina o fale suʻesuʻe ma tupe faʻaalu.
●System i le Igilisi ma le Saina, lea e mafai ona fesuiai saoloto.
●O le nofoaga e pulea le vevela e mafai ona faʻaigoaina saoloto e le tagata faʻaoga, lea e faigofie mo tagata faʻaoga.
●Fa'aaogaina o le multiprocessor parallel work mode, sili atu le mautu ma fa'atuatuaina.E fetaui ma au'ili'iliga fa'ata'ita'iga lavelave.Fa'aauupegaina i le tele o su'esu'ega maualuga e pei ole FID, TCD, ECD, ma le FPD.E oʻo atu i le fa suʻega e mafai ona faʻapipiʻi i le taimi e tasi.E mafai foʻi ona faʻaogaina le auala faʻaopoopo faʻamatalaga, lea e faigofie ona faʻatau ma faʻapipiʻi isi mea faʻapipiʻi pe a uma ona faʻatau le meafaigaluega.
●O le meafaigaluega e faʻaaogaina le fausaga faʻapitoa, mamanuina ma suia, faigofie ona faʻaleleia ma puipuia le aoga o tupe teufaafaigaluega.
●Ole faiga fou ole fa'aogaina ole vevela ole microcomputer e iai le sa'o lelei ole fa'atonuina ole vevela ma le fa'amaoni sili atu ma le fa'alavelave fa'alavelave.E ono tuto'atasi faiga pulea vevela, lea e mafai ona iloa 16-laasaga vevela polokalame, lea e sili atu le gafatia o meafaigaluega e suesue faataitaiga.O loʻo i ai se faʻaoga otometi pito i tua mo le ogaumu, lea e faʻaleleia ai le saʻo o le maualalo o le vevela ma faʻateleina le saoasaoa o le maualuga / faʻaititia.
●O le meafaigaluega e mafai ona faʻapipiʻiina i le faʻaogaina o le eletise eletise (EFC) ma le eletise eletise eletise (EPC) e iloa ai le faʻaogaina o numera, lea e mafai ona faʻaleleia atili ai le toe faʻaleleia o taunuʻuga faʻapitoa ma faʻatusatusa.
●E faigofie ona fa'amae'a su'esu'ega i luga ole laiga o fa'ata'ita'iga kesi o le mea faigaluega fa'atulagaina taimi (e mana'omia i luga ole laiga ni vaega tui fa'atotonu).
●O le faʻaogaina o le microcomputer control keyboard e faigofie ma faigofie ona faʻaogaina;ma ua mamanuina le tekinolosi faʻamatalaga otometi o le mea e iloa ai.Fa'atasi ai ma fa'ailoga fa'aletonu ma le puipuiga o fa'amaumauga o le malosi-off, e mafai ona otometi ona taulotoina fa'amau.
●O le meafaifaaili e iai le leo maualalo, maualuga 24-bit AD circuit fa'atasi ma le teuina o le laina ma le toesea o laina faavae.
●Aoina faailoilo chromatographic ma faʻamaumauga faʻamaumauga, talafeagai mo WinXP, Win2000, Windows7 ma isi faiga faʻaoga.O fa'amatalaga fa'ata'ita'iga e faitau mai faila CDF e fetaui ma tulaga A/A (American Analytical Society), ina ia mafai ona fa'aoga i Agilent, Waters ma isi fale faigaluega chromatography.
●Chromatographic system fa'atasi ai ma aia tatau fa'ale-mafaufau tuto'atasi, fa'atasi ai ma fa'ata'ita'iga masani o le MODBUS/TCP, e faigofie ona fa'apipi'i i le DCS.
●O le meafaigaluega e mafai ona fesoʻotaʻi ma le faʻataʻitaʻiga taʻavale na gaosia e le tele o fale gaosi oloa i totonu ma fafo;e pei o Shimadzu AOC-20i, HTA kamupani HT faasologa maualuga-lelei vai, kesi taavale sampler.
Su'e kasa | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.(7 kasa),O2(filifiliga), N2 (filifiliga) |
Dta'aloga | 192*64 mata'itusi LCD |
Vaega e pulea le vevela | 6 auala |
Fa'atonuga o le vevela | vevela potu +5℃~400℃, fa'aopoopo 1℃, sa'o:±0.1℃ |
Polokalama fa'atonuga | 16 laasaga |
Polokalame si'itia fua | 0.1~40℃/min |
Pulea kesi | faiga fa'atonutonu alavai fa'ainisinia, fa'aeletonika fa'amanino fa'amama fa'atonu auala fa'atonu |
Mea e tutupu i fafo | 4 alavai |
Ituaiga tui | fa'apipi'i koluma, capillary, ono-ala valve kesi tui, tui otometi headspace, ma isi. |
Numera o fa'amatalaga | 4pcs;FID, TCD, ECD, FPD (filifiliga) |
Amata tui | tusi lesona, otometi e filifili |
Feso'ota'iga feso'ota'iga | Ethernet: IEEE802.3 |
Fa'amatalaga Fa'amatalaga | |
Su'esu'e o le afi mumu (FID) | |
Fa'atapula'a su'esu'ega | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
Pisao faavae | ≤ 5 × 10-14A |
Fa'ase'e fa'avae | ≤ 1 × 10-13A / 30min |
laina laina | ≥106 |
Su'esu'ega Fa'avevela (TCD) | |
Ma'ale'ale | S≥2500mV•ml/mg (benzene/toluene) (fa'atele 1, 2, 4, 8 taimi e filifili ai) |
Pisao faavae | ≤20μV |
Fa'ase'e fa'avae | ≤30μV/30min |
laina laina | ≥104 |
Fa'amatalaga pu'e fa'aeletonika (ECD) faitalia | |
Fa'atapula'a su'esu'ega | ≤ 1 × 10-13g / ml (propylene hexa-6 / isooctane) |
Pisao faavae | ≤0.03mV |
Fa'ase'e fa'avae | ≤0.2mV/30min |
laina laina | 103 |
Punavai leitio | 63Ni |
Su'esu'e Ata Fua (FPD) faitalia | |
Fa'atapula'a su'esu'ega | (S) ≤ 5×10-11g / s, (P) ≤ 1×10-12g/s;methyl parathion/ ethanol atoatoa) |
Pisao faavae | ≤ 3 × 10-13A |
Fa'ase'e fa'avae | ≤ 2 × 10-12A / 30min |
laina laina | Fpo'o le sulfur ≥ 102, mo phosphorus ≥ 103 |
Kesi Chromatograph Vaega Autu | 1 seti |
Fa'asuavai afi | 1 seti |
Ea afi | 1 seti |
Fa'asao tele-galuega | 1 seti |
Valve Fa'aitiitiga Fa'aitiitiga Fa'atonu | 1 seti |
Valve Fa'aitiitiga Fa'aitiitiga o le Nitrogen | 1 seti |
Tu'u Nitrogen | 1 fagu |
kesi masani | 1 fagu |
Nati ala kesi M8X1Φ3.2 | 10 pcs |
So'oga alavai fa'aitiitiga o le mamafa | 5 pcs |
Nut koluma capillary Φ0.8 | 4 pcs |
Nut koluma Φ4.2 ma le Φ3.2 | E ta'i 5 pcs |
u'amea uamea kasa totonu paipa Φ2 | 10 pcs |
Ala kesi fa'amaufa'ailoga | 50 pcs |
Capillary sampler evaporative pad | 50 pcs |
Capillary graphite pad Φ0.8 | 20 pcs |
Papa kalafi Φ4.2 ma le Φ3.2 | Ta'itasi 10 pcs |
Fuse | 4 pcs |
Siu M3X5 | 6 pcs |
PE kesi paipa Φ3 | 20m |
1ml injector palasitika | 5 pcs |
100ml tui | 5 pcs |
nila | 10 pcs |
20ml ipu tioata | 5 pcs |
5ml ipu tioata | 5 pcs |
1ml ipu tioata | 5 pcs |
Kilipa quantitative | 2 pcs |
Vaseline 30g | 2 pcs |
Sikuli fa'ailoga 50mm 70mm | Ta'itasi 1 pc |
Sikuli fa'aulu 50mm 70mm | Ta'itasi 1 pc |
Su'e 8-10 | 1 pc |
Su'e 12-14 | 2 pc |
Ma'ai tui isu | 1 pc |
Uaea eleele | 1 pc |
Uaea faailo | 1 pc |
Uaea eletise | 1 pc |
pulou pa'u | 20 pc |
Ato pepa alumini | 2 pcs |
nila fa'alua | 25 pcs |
Disk | 1 pc |
Uaea feso'ota'iga | 1 pc |
Poloka kesi | 1 pc |