GD3127 Fa'asologa Maualuga Voltage Insulation Resistance Tester
GD3127 Series Insulation Resistance Tester o loʻo faʻaaogaina lautele i le tausiga o mea eletise i le transformer substation, fale eletise, ma isi. E fetaui lelei mo le faʻatinoina o le fuaina o le faʻaogaina o le insulation resistance (IR), polarization index (PI), absorption ratio (DAR), ramp ( RAMP), faamama (FR, 10s, 20s, 30s, 40s 4 filifiliga), voltage (V), o loʻo iai nei (nA) o ituaiga uma o meafaigaluega eletise maualuga, e aofia ai switchgear, transformers, reactors, capacitors, motors, generators ma uaea, ma isi.
GD3127 Fa'asologa o le meafaigaluega su'esu'e atoatoa mo le vave iloa ma le mauaina o puipuiga po'o fuafuaga fa'aleleia mo mea e ono fa'aletonu.E taua tele le faʻamautinoaina o le lelei o oloa ma le saogalemu o tagata ma meafaigaluega o loʻo faʻaogaina.O le faʻaogaina o le faʻaogaina o oloa eletise o se tasi lea o faʻailoga taua e iloilo ai le lelei o le insulation, lea o loʻo atagia mai i le suʻega faʻamalosi.
●Max.pu'upu'u taimi> 5mA.
●Insulation resistance(IR), polarization index(PI), absorption ratio(DAR).
●Ramp(RAMP), faamama(FR), voltage(V).
●Otometi le mata'ituina o le voluma ola o le mea ua fuaina, ma otometi fa'asa le su'ega pe a sili atu le voltage i le 36V, lea e puipuia lelei ai le meafaigaluega ma le tagata fa'afoe.
●Taimi galuega, fa'amaumau otometi le taimi su'ega.
●Fa'ato'a fa'ate'a le voluma maualuga pe'ā mae'a le fua, o le taimi fa'ate'a e le sili atu i le 30 sekone.
●Otometi le paoa galuega.
●Fa'aaliga mata'itusi mata'i LCD tele ma fa'atinoga mautu.
●Fausia atigi fa'alua-lau, malosi ma umi, puipuiga grade IP65.
●Ma'a lithium e mafai ona fa'aaogaina tele.
●Galuega Teuina, e mafai ona otometi ona teuina 1000 seti o faʻamaumauga faʻataʻitaʻi taimi faʻatasi ma le aso ma le taimi o suʻega ma le taimi o suʻega.
●Faʻapipiʻi galuega, faʻapipiʻiina i le USB interface, faʻamaumauga faʻamaumauga e mafai ona faʻapipiʻiina i le komepiuta mo suʻesuʻega faʻamaumauga o faʻamaumauga.
Galuega | Insulation resistance(IR), polarization index(PI), absorption ratio (DAR), ramp (RAMP), faamama (FR, 10s, 20s, 30s, 40s 4 filifiliga), voltage(V), current(nA) |
Paoa sapalai | Toe fa'aaogainamaa lithium5.2A |
Fuafuaina voltage | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
Volosa gaosi asa'o | (5%-10%)±10V |
Fa'ato'a fa'agata fua fa'atatau | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
A'oga ta'avale pupuu | >5mA |
Fa'ailoga fa'apolokalame(PI) | Ioe |
Ole fua ole miti (DAR) | Ioe |
Faiga su'ega Ramp(RAMP). | Fa'ata'ita'i i la'asaga o le 10% o le voli fa'atonu se'ia o'o i le vili fa'atonu |
Filifili faiga su'ega | Fa filifiliga o le 10S, 20S, 30S, 40S |
Su'ega o le galu | Va'aiga: AC/DC 0V-1000V, sa'o:±5%rdg±3V |
Su'ega o iai nei | Va'aiga: 0.01nA-7mA, sa'o:±5%rdg±0.5nA |
Mataitu voli | Mataʻituina le voltage o le mea faʻataʻitaʻi, mataʻituina le tulaga faʻamalo pe a uma le suʻega, ma faʻasaina le suʻega pe a sili atu le voltage nai lo le 36V, puipuia le meafaigaluega ma le tagata faʻatautaia |
Taimi su'ega | Fa'amaumau otometi le taimi o su'ega, taimi fa'asologa: 0s~9999s |
Teuina | Otometi le teuina o faʻamatalaga suʻega ma le aso ma le taimi, o le aofaʻi o 1000 vaega |
Fesootaiga | Tu'u atu fa'amaumauga o su'ega na teuina i le komepiuta e ala i le laina feso'ota'iga USB. |
Ma'a | O lo'o i ai se fa'aaliga maualuga o le maa, fa'amanatu e fa'aola i le taimi e maualalo ai le voli o le maa |
Otometi mape le galuega | Pepe le eletise pe a uma le 15 minute |
Vasega puipuiga | IP65/IP40 |
Tete'e puipui | 50MΩ(1000V) (i le va o su'ega su'ega ma atigi) |
Taofi le voltage | AC 3kV 50Hz 1min (i le va o su'ega su'ega ma atigi) |
Tulaga | IEC61010-1, IEC61326-1 |
Galulue vevela ma susū | - 20℃ ~ +50℃ <80%RH |
Teuga vevela ma le susū | - 25℃ ~ +65℃80%RH |
Paoa sapalai | 220V AC 50Hz |
Fua (mm) | 280(L)*260(W)*160(H) |
mamafa | 4400g(e aofia ai maa) |
Su'e fa'alumaina | 1 seti |
Uaea su'ega eletise maualuga (Lanu mumu) | 1 fasi |
Su'e uaea(Lanu meamata) | 1 fasi |
Su'egauaea(Lanu uliuli) | 1 fasi |
Su'ega eletise | 1 ituiece |
tagata fa'aoga's taiala | 1 kopi |
Su'egareport | 1 kopi |