GD3126A (GD3126B) Su'ega Fa'a'ese'ese 5kV/10TΩ (10kV/20TΩ)
GD3126A (GD3126B) Insulation Resistance Tester o loʻo faʻaaogaina lautele i le tausiga o mea eletise i le transformer substation, power plant, ma isi. E talafeagai mo le faʻatinoina o le fuaina o le faʻaogaina o le insulation resistance (IR), absorption ratio (DAR), polarization index (PI), leakage i le taimi nei (Ix) ma absorption capacitance (Cx) o ituaiga uma o meafaigaluega maualuga voltage, e aofia ai switchgear, transformers, reactors, capacitors, motors, generators ma uaea, ma isi.
●Fa'aaogaina le fa'atonuga microcomputer, fa'agaioiga lisi ma fa'aaliga mata'itusi mata tele LCD ma fa'atino mautu.
●Malosi o le faʻalavelave faʻalavelave, talafeagai mo le fuaina i totonu o le siosiomaga faʻalavelave eletise eletise malosi.
●Tele gafatia, e mafai ona faʻamalieina manaʻoga o le eletise maualuga, maualuga le teteʻe, tele suʻega uta gafatia.
●Faatasi ai ma le faʻalavelave faʻafuaseʻi, susu-faʻamaonia ma le pefu-faʻamaonia fausaga, faʻafetaui i le siosiomaga faigaluega faigata.
●Fa'aoga fa'aoga, fa'aali fa'ai'uga sa'o ma suiga o fa'amaumauga.
●Fa'atonuga lelei o le puipuiga, e mafai ona tatalia le a'afiaga o le va'aiga pu'upu'u ma le fua fa'atatau o le voluma totoe.
●5 laʻasaga o le gaosiga o le eletise o 250 V, 500V, 1.0kV, 2.5kV, 5.0kV.
●6 laʻasaga o le gaosiga o le voltage o 250 V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV.Ole maualuga maualuga ole la'asaga ta'itasi e fa'aauau ona fetu'una'i mai le zero.
●E mafai foi ona fa'aauau pea ona fetu'una'i le voluma maualuga.
●Fuafuaga otometi o le R15, R60, R600, fua fa'atatau o le absorption, fa'ailoga polarization.
●Ole maualuga ole fua ole fua ole 0~10TΩ (0~20TΩ), otometi fesuia'i laina.
●Fuaina otometi o le vevela ambient, susū o le ea ma le taimi o suʻega.
●Fa'aali le taimi o le su'ega, fa'ailo fa'auta i 15 sekone uma, 5 minute e aunoa ma se fa'agaioiga e vave tapuni.
●Fa'ato'a fa'ate'a le voluma maualuga pe'ā mae'a le fua, o le taimi fa'ate'a e le sili atu i le 30 sekone.
●Teuina o 60 vaega o fua fua, nonvolatility mo 20 tausaga..
●Faatasi ai ma le RS232 serial interface, mafai ona fesoʻotaʻi faʻamatalaga ma komepiuta.
●Faatasi ai ma le lomitusi fafo, e mafai ona lolomi fua fua.(filifiliga)
●O le voltage o le fa'ata'ita'iga ua molia o lo'o fa'aalia a'o le'i faia le su'ega ma e iai fa'amatalaga talafeagai.
●Taimi fa'ata'ita'i fa'ata'ita'i, otometi ona taofi le fua;
●Mafai ona iloa le leakage o lo'o iai nei Ix ma absorption capacitance Cx.
Laasaga ole su'ega ole su'ega | GD3126A (5kV) GD3126B (10kV) | ||||||
250V, 500V, 1.0kV, 2.5kV, 5.0kV, 10kV | |||||||
Fa'aoso le mea sese | ±5% | ||||||
Tete'e laina | Tapulaa pito i luga | 500GΩ~10TΩ | |||||
tapulaa maualalo | 0.1MΩ | ||||||
Vasega sa'o | 5.0 vasega | ||||||
Fa'aaliga fa'aaliga maualuga maualuga | ±( 5%•Ux + 1numera ) | ||||||
Lisi le taimi nei Ix fua fua & sese | 0.1nA~9.9mA 5% | ||||||
Absorption capacitance Cx fua fua & sese | 0.1pF~99ɥF 5% | ||||||
Sese le fuaina o le vevela | ±0.5℃ | ||||||
Sasi le fuaina o le susu | ±2%RH | ||||||
A'oga ta'avale pupuu | <6mA | ||||||
galugalu galu | <3% | ||||||
Taimi su'ega | E oʻo i le 99 minute | ||||||
Tete'e puipui | > 500 MΩ (i le va o le uaea su'ega ma le pusa) | ||||||
Taofi le voltage | AC10.0kV 50Hz 1min (i le va o le uaea su'ega ma le pusa) | ||||||
Paoa sapalai | 12V maa lithium | ||||||
Taimi tautua ma'a pe a uma ona fa'ae'e tasi | 30 aso 10 taimi DAR & 5 taimi PI suega i le aso | ||||||
Galulue vevela ma susū | 0℃ ~ + 40℃ <85%RH | ||||||
Teuga vevela ma le susū | - 20℃ ~ + 50℃ <90%RH | ||||||
Paoa sapalai | 220V AC 50Hz | ||||||
Fua (mm) | 325 (L)*250(W)*130(H) | ||||||
mamafa | 3.7kg | ||||||
Mea sese fua o le tetee | |||||||
Laasaga o le galu | 250 V | 500 V | 1.0 kV | 2.5 kV | 5.0 kV | 10KV | |
±( 3%·Rx + 1d ) | 1GΩ | 2GΩ | 4GΩ | 10GΩ | 20GΩ | 40GΩ | |
±( 5%·Rx + 1d ) | 10GΩ | 20GΩ | 40GΩ | 0.1TΩ | 0.2TΩ | 0.4TΩ | |
±( 10%·Rx + 2d ) | 100GΩ | 200GΩ | 0.4TΩ | 1TΩ | 2 TΩ | 4TΩ | |
±( 25%·Rx + 2d ) | 500GΩ | 1TΩ | 2TΩ | 5TΩ | 10TΩ | 20TΩ |
Su'e fa'alumaina | 1 seti |
Su'ega uaea feso'ota'i mo le laina L (Mula) | 1 a'a (1 vaega) |
Su'ega uaea feso'ota'i mo G terminal (Green) | 1 a'a (1 vaega) |
Su'ega uaea feso'ota'i mo E fa'amau (uliuli) | 1 a'a (1 vaega) |
3APower adapter (Mo lomitusi sapalai eletise ma meafaigaluega e molia) | 1 ituiece (1 vaega) |
RS232 laina feso'ota'iga fa'asologa | 1 a'a (1 vaega) |
tagata fa'aoga's taiala | 1 kopi (1 vaega) |
Lipoti o Su'ega | 1 kopi (1 vaega) |
1. L fa'amau fa'amau 2. G fa'amau fa'amau 3. E fa'amau fa'amau 4. LCD mata
5. Pisi 6. Temperature & susū fa'amau 7. ESC faamau 8. UP faamau
9. Kipi fa'atusatusa 10. Fa'amau i lalo 11. Fa'amau OK12. High voltage fetuutuunai ki
13. RS232 fa'aoga 14. Kilia eletise15. Socket fa'atumu