GD2000D Insulation Resistance Tester
GD2000D digital insulation resistance su'ega na gaosia e la matou kamupani fa'aaogaina se masini fa'aogaina fa'apisinisi fa'ato'a fa'aogaina i le taimi moni.O le fa'asinoala fa'akomepiuta analog ma fa'aaliga numera numera fanua fa'aaliga ua atoatoa tu'ufa'atasia.O lenei faasologa o mita o loʻo i ai le tele o tulaga eletise eletise (250V, 500V, 1000V, 2500V, 5000V, 10000V), malosi tele, malosi faʻalavelave faʻalavelave, faʻamatalaga analog ma faʻaaliga faʻafuainumera, AC ma DC faʻaoga lua, faʻaoga faigofie, fuafuaina otometi o faailoga insulation eseese (absorption ratio, polarization index), fua fua eseese ma galuega anti-mana-lalo, ma isi O se meafaigaluega suʻesuʻe lelei mo le fuaina o le insulation tetee o transformers tetele, transformers, generators, maualuga- afi eletise, capacitors eletise, uaea eletise, ma pu'e uila.
DL/T 474-2006 "Ta'iala mo Su'ega Insulation i luga ole nofoaga"
DL/T 845-2004 "Fa'amatalaga lautele mo le fuaina o mea e tete'e"
DL/T 846-2004 "Fa'amatalaga fa'apitoa fa'apitoa mo mea faigaluega su'esu'e maualuga"
DL/T 596-2005 "Faiga su'ega puipuia mo meafaigaluega eletise"
GB50150-2006 "Tulaga mo le suʻega tuʻuina atu o meafaigaluega eletise eletise faʻapipiʻiina masini eletise"
GB/T16927.1 ~ 2-1997 "Mata'iga su'ega volimau maualuga"
GB4793-1984 "Faʻamaopoopoina faʻapipiʻi mo le maualuga o le eletise eletise ma le tufatufaina o meafaigaluega"
1. Voltage gaosiga (250V / 500V / 1000V / 2500V / 5000V) .Tagata tetee 0-200GΩ.
2. E lua auala e fa'aalia ai le fa'alumaina.
3. Fuafuaga absorption Auto-fa'atatau ma fa'ailoga polarization.
4. Fa'agaioiga fa'auo, fa'aola fa'aauau 19times fua fua.
5. Fa'ato'a-fa'a'ave'esea toega maualuga maualuga pe a uma le su'ega.
6. AC/DC power supply, fa'atasi ai ma maa toe fa'aaogaina po'o AC adapter.
7. Malosi fa'alavelave fa'alavelave, faitau mautu ma fa'atuatuaina.
8. Fuafuaga feaveai, talafeagai mo galuega vao.
9. Puupuu le taimi nei ≥3mA, meafaigaluega lelei mo le suʻeina o le insulation resistance o le transformer tele, inductor, generator, HV motors, eletise eletise, uaea ma siʻitia puʻe.
Mea Nu. | GD2000D | ||||||
Volosa gaosi | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
Sa'o | vevela | 23℃±5℃ | |||||
Tete'e puipui | 250-5G ±5% | 50-10G ±5% | 1M-20G ±5% | 2.5M-50G ±5% | 5M-100G ±5% | ||
Isi vaega: ±10% | |||||||
Volosa gaosi | 2M-10G ±5% | 4M-20G ±5% | 8M-40G 0--+10% | 20-100GΩ 0 --+10% | 40-200G 0-- +10% | ||
Sli'o li'o pu | ≥3mA | ||||||
Paoa sapalai | 8*AA ituaiga maa maualuga e mafai ona toe fa'aaogaina & fa'apipi'i fafo | ||||||
Galulue Temp. & Susūsū | -10 ℃--40 ℃, maualuga. susū fa'atatau 85% | ||||||
Teuga Temp. & Susū | -20 ℃--60 ℃, maualuga. susū fa'atatau 90% | ||||||
Insulation | Max.2000MΩ pe a voltage i le va o le matagaluega ma atigi e 1000VDC. | ||||||
Taofi le voltage | Taofi le 1min pe a o'o le voltage i le va o le li'o ma le atigi3kV50Hz SiniAC voltage | ||||||
Fua | 230mm*190mm*90mm (L*W*H) | ||||||
mamafa | 3kg |
Su'e fa'alumaina | 1 seti |
Su'e uaea | 1 fasi |
Su'ega eletise | 1 fasi |
Uaea eletise | 1 fasi |
Taiala a Tagata Fa'aoga | 1 kopi |
Tusi Faamaonia | 1 kopi |