GD-7018A Optical Fiber Identifier
O le GD-7018 faasologa opitika alava pipeline e iloagofie e mafai ona saʻo suʻe ma fua loloto o le lalo o le eleele pipelines, uaea ma opitika uaea i lalo o le tulaga e aunoa ma le eliina, ma maua saʻo mea leaga o le ufiufi pito i lalo o le eleele pipelines ma le nofoaga o le. mea faaletonu uaea i lalo o le eleele.O le meafaigaluega e aofia ai tekinolosi sili ona maualuga e pei o le ultra-narrow band filter, Bluetooth wireless communication, GPS positioning, otometi fa'afanua fa'afanua e ala i fa'apolofesa su'esu'ega fa'amatalaga fa'apolofesa ma otometi fa'atupuina o lipoti su'ega.O le suʻesuʻeina ma le suʻesuʻeina o ituaiga uʻamea uʻamea, pulega ma le tausiga o paipa, fuafuaga a le malo ma le fausiaina, suʻesuʻeina o paipa i le eletise ma isi matagaluega o se tasi lea o meafaigaluega manaʻomia mo iunite faʻaleleia paipa.
(1) Galuega e tele
1. Transmitter galuega: E tolu faʻailoga faʻaoga auala o le induction auala, auala tuusaʻo ma auala pipii, talafeagai mo taimi eseese.
2. Receiver galuega: Faʻaaogaina e fua ai le nofoaga, faʻatonuga, loloto tanumia ma le taimi nei i lalo o le eleele paipa ma uaea.
3. O aū tu'uaga agavale ma taumatau o lo'o ta'u mai ai le nofoaga o le paipa fa'amoemoe, ma o le nofoaga e vave ma sa'o;o aū pito i luma ma tua ma le tau o le dB o loʻo faʻaalia ai le nofoaga ma le lapopoa o le mea faʻaleagaina o le vaega anticorrosive.
4. Faʻatasi ai ma le backlight function, talafeagai mo laveaʻi faʻafuaseʻi i le po.
5. GPS fa'afanua fa'atulagaina galuega, fa'afanua otometi pipeline.
6. Polokalama su'esu'ega fa'apolofesa fa'apolofesa, fa'atupu otometi o lipoti su'ega.
7. O galuega faʻapitoa a le 7018E receiver: E faʻaaogaina e suʻe ai faʻaletonu (paipa faʻaletonu o loʻo faʻatatau i le faʻaleagaina o le pito i fafo o le anti-corrosion layer, le faʻaogaina o le uaea e faʻatatau i le faʻaleagaina o le puipui puipui fafo), ma ia iloa ai le faʻaleagaina o le insulation. o paipa i lalo o le eleele.
8. Fua i le taimi nei: fua le taimi nei e faʻaogaina e le transmitter i le paipa i lalo o le suʻega.
9. Multimeter galuega: e mafai ona fuaina le voluma, laina laina, laina i le taimi nei, impedance ma le mana.Fa'ata'ita'i le fa'aauau ma le tulaga fa'a'ese'esega o le uaea a'o le'i mae'a su'esu'ega fa'aletonu uaea.
10. Faʻapipiʻi faʻapipiʻi fafo: talafeagai mo le nofoaga e le mafai ona fesoʻotaʻi saʻo le faailo pe a iloa le uaea.
(2) Tulaga maualuga maualuga
1. O ituaiga eseese o fua mo le faʻatulagaina o paipa (valley mode, peak mode, wide peak mode, peak arrow mode) e mafai ona faʻamaonia faʻamaonia e faʻamautinoa ai le saʻo o le faʻatulagaina o paipa.
2. Auala aupito maualuga: auala pito i luga, ala pito i luga lautele, ala arrow pito i luga e mafai ona faʻaaogaina e fua ai le suiga o le vaega faalava ((HX)) poʻo le gradient faʻalava (△HX), ma suʻe e tusa ai ma le tulaga o lona tau maualuga;
3. Le auala aupito maualalo: Faʻaaoga le pito i lalo e fuafua ai le tulaga o le tau maualalo e ala i le fuaina o le suiga o le vaega tuʻu (HZ).
(3) E tele auala faʻalogo
1. O auala eseese e iloa ai e mafai ona filifili fa'apitoa ma mafai ona fa'amaonia fa'atasi.
2. Auala faitau sa'o ma vili fa'ata'i lua.
3. tulaga tasi coil 80% auala, 50% auala.
4. 45 tikeri auala.
(4) Malosi e tetee atu i le faalavelave
1. Le tele o fa'amaufa'ailoga mata'ituina: vaega fa'alava (HX), vaega tu'usa'o (HZ) ma le fa'ata'atia (△HX) e mafai ona fuaina.
2. Malosiaga faʻasalalau maualuga: O le gaosiga o le eletise e oʻo atu i le 10W ma o loʻo faʻaauau pea ona fetuunai.E mafai ona filifili fa'apitoa e tusa ai ma mana'oga.
3. Fa'ateleina ala faigaluega:
Fa'avevela taimi: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Fa'atelega o tagata e mauaina: leitio, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. E tusa ai ma uiga o le paipa sini (meafaitino, fausaga, tanumia loloto, umi, ma isi), filifili le taimi faigaluega talafeagai.
(5) Faigofie le faagaoioiga
1. Intuitive: O se faʻaaliga faʻataʻitaʻiga e faʻaaogaina e faʻaauau ma faʻaalia taimi moni taʻiala eseese ma faʻailoga malosi i le taimi o le suʻesuʻeina.
2. Otometi: Otometi fesuiaʻi i le tulaga lua antenna mode ma otometi fetuutuunai lagona le taliaina pe a fuaina le loloto, ina ia ausia le faailo sili fua, ma toe foi otometi i le faiga galue ao lei maea.
(6) Taimi faigaluega faifaipea umi ma tau fa'aoga maualalo
O loʻo faʻapipiʻiina le transmitter i se pusa eletise lithium tele, lea e mafai ona faʻamalieina manaʻoga manaʻomia o le tasi aso fanua mo le suʻesuʻeina o fanua e tasi le totogi, ma e mafai ona toe faʻaaogaina, lea e faʻaitiitia ai le tau o le suʻesuʻeina.
(7) Transmitter --AC ma DC fa'aoga lua
I lalo o tulaga masani, afai e tumu le maa transmitter, faʻaaoga le pusa o loʻo fausia i totonu e tuʻuina atu ai le mana.Afai i le taimi o le faʻaaogaina, e maualalo le maa transmitter, ae e leʻi maeʻa le galuega suʻesuʻe, e mafai ona e faʻafesoʻotaʻi saʻo se mea faʻapipiʻi eletise tuʻufaʻatasia, e mafai ona faʻaaoga masani le meafaigaluega, e aunoa ma le faʻatali mo le meafaifaʻaili e faʻatumu atoa aʻo leʻi faʻaaogaina.
Fua Fa'atekinisi | Afa'asologa | Bfa'asologa | Cfa'asologa | Dfa'asologa | Efa'asologa |
Su'eina Auala | 5 | 6 | 7 | 8 | 10 |
Fa'atele | 512,1K,33K,83K | 512,1K,33K,83K | 512,1K,33K, 83K | 512,1K,33K,65K,83K | 512, 1K, 2K, 33K, 65K, 83K |
Fa'asao Fa'atele | 50Hz | 50Hz 100Hz | 50Hz 100Hz leitio | 50Hz 100Hz leitio | 50Hz 100Hz leitio |
Filifiliga Malosi | × | × | √ | √ | √ |
Fa'atele Fa'aletonu | × | × | × | × | 2 |
Su'e masei | × | × | × | × | √ |
Lithium ion maa | √ | √ | √ | √ | √ |
Se Fa'avaa | × | × | × | × | √ |
Su'eina le loloto(m) | 6 | 6 | 6 | 6 | 6 |
Teuga o fa'amaumauga | × | × | × | √ | √ |